modelPVPlantSolarIrradiance

PV source in a SMIB system to test functionality of Irradiance to Power Add on

Extends from BaseClasses.SMIBAddOn (SMIB - Single Machine Infinite Base system with one load for renewable source validation.).

Information

Simulate for 5 seconds.

This test system aims to show how to use IrradianceToPower block, an Add-On component that enables varying active power reference in the PV model based on irradiance levels. This capability is not found in the original version of the WECC-based renewable models.

Variables of interest:

  • pV.RenewableGenerator.Pgen
  • pV.RenewableGenerator.Qgen
  • irradianceToPower.Ppv

Components

TypeNameDefaultDescription
OpenIPSL.Electrical.Branches.PwLinepwLine (from SMIBAddOn)
OpenIPSL.Electrical.Branches.PwLinepwLine1 (from SMIBAddOn)
OpenIPSL.Electrical.Branches.PwLinepwLine2 (from SMIBAddOn)
OpenIPSL.Electrical.Events.PwFaultpwFault (from SMIBAddOn)
OpenIPSL.Electrical.SystemBaseSysData (from SMIBAddOn)
OpenIPSL.Electrical.Buses.BusPV_BUS (from SMIBAddOn)
OpenIPSL.Electrical.Buses.BusFAULT (from SMIBAddOn)
OpenIPSL.Electrical.Buses.BusGEN2 (from SMIBAddOn)
Electrical.Sources.VoltageSourceReImInputvoltageSourceReImInput (from SMIBAddOn)
Modelica.Blocks.Sources.RealExpressionimagPart (from SMIBAddOn)
Modelica.Blocks.Sources.RealExpressionrealPart (from SMIBAddOn)
Electrical.Renewables.PSSE.PVPV
Electrical.Renewables.PSSE.AddOnBlocks.IrradianceToPowerirradianceToPower
Electrical.Loads.NoiseInjections.WhiteNoiseInjectionwhiteNoiseInjection
Modelica.Blocks.Math.Addadd
Modelica.Blocks.Noise.GlobalSeedglobalSeed
Modelica.Blocks.Nonlinear.Limiterlimiter