modelMetformin_Stepensky2002_PD_r
indirect_response_i exposure-response sweep — Stepensky_2002 :: R (blood glucose levels)
Extends from Pharmacolibrary.Interfaces.PartialExposureResponseSweep (static exposure-response curve in which TIME IS THE SWEEP AXIS, not time).
Information
Metformin_Stepensky2002_PD_r
The steady-state exposure-response curve of Stepensky D et al., Drug metabolism and disposition: the biological fate of chemicals 30(8):861–868 2002 (doi:10.1124/dmd.30.8.861) — blood glucose levels [mg/100 ml] against metformin µg — obtained by sweeping the driver instead of simulating a dose. Model family: indirect_response_i.
The parameters, in the paper's terms
E0 = 383.763837638 mg/100 ml drug-free response (baseline) (kin/kout, Q327/Q328) Emax = 0.486 maximal effect term (E_max GI, Q323) EC50 = 431 µg exposure at half of the maximal effect term (EA_50 GI, Q321) gamma = 2 Hill coefficient (n_GI, Q325)
The algebra is response = E0*(1 - Emax*frac); this model only supplies the numbers. The x axis is one µg of metformin per second of simulated time (exposure is in kg): there is no state, no dose and no kinetics — plot response against exposure (or time).
What it reproduces
exposure = 0 response 383.8 (drug-free) exposure = EC50 (431 µg) response 290.5 exposure -> infinity response 197.3
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Real | E0 (from PartialExposureResponseSweep) | 0 | response with no drug |
| Real | Emax (from PartialExposureResponseSweep) | 1 | maximal effect term — how it enters the response is set by the extending class |
| Real | EC50 (from PartialExposureResponseSweep) | 1 | exposure at half of the maximal EFFECT TERM (D50, for a dose sweep) |
| Real | gamma (from PartialExposureResponseSweep) | 1 | Hill coefficient |
| Real | exposure_per_s (from PartialExposureResponseSweep) | 1.0 | exposure units per second of simulated time — the sweep rate |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Real | exposure (from PartialExposureResponseSweep) | the driver being swept: a concentration, or a dose | |
| Real | frac (from PartialExposureResponseSweep) | Hill fraction, 0..1 — the shared part of every exposure-response shape | |
| Real | response (from PartialExposureResponseSweep) | modelled response at that exposure |
Revisions
- 11/2026 generated by pharmacolibrary-dev export.pharmacolibrary_models from Stepensky_2002: parameters extracted from the paper by the pharmacolibrary-dev pipeline, model built by its engineer, reviewed: curated candidate