modelFinasteride_Ko1995_PD_dht

indirect_response_i exposure-response sweep — Ko_1995 :: DHT (DHT concentrations)

Extends from Pharmacolibrary.Interfaces.PartialExposureResponseSweep (static exposure-response curve in which TIME IS THE SWEEP AXIS, not time).

Information

Finasteride_Ko1995_PD_dht

The steady-state exposure-response curve of Ko HC et al., Pharmacotherapy 15(4):509–511 1995 — DHT concentrations against finasteride ng/ml — obtained by sweeping the driver instead of simulating a dose. Model family: indirect_response_i.

The parameters, in the paper's terms

  E0    =        100          drug-free response (baseline) (kin/kout, Q327/Q328)
  Emax  =        0.7          maximal effect term (Emax, Q323)
  EC50  =      0.012 ng/ml    exposure at half of the maximal effect term (IC50, Q322)
  gamma = (library default) Hill coefficient

The algebra is response = E0*(1 - Emax*frac); this model only supplies the numbers. The x axis is one ng/ml of finasteride per second of simulated time (exposure is in kg/m3): there is no state, no dose and no kinetics — plot response against exposure (or time).

What it reproduces

  exposure = 0         response 100   (drug-free)
  exposure = EC50 (0.012 ng/ml)  response 65
  exposure -> infinity  response 30

Parameters

TypeNameDefaultDescription
RealE0 (from PartialExposureResponseSweep)0response with no drug
RealEmax (from PartialExposureResponseSweep)1maximal effect term — how it enters the response is set by the extending class
RealEC50 (from PartialExposureResponseSweep)1exposure at half of the maximal EFFECT TERM (D50, for a dose sweep)
Realgamma (from PartialExposureResponseSweep)1Hill coefficient
Realexposure_per_s (from PartialExposureResponseSweep)1.0exposure units per second of simulated time — the sweep rate

Components

TypeNameDefaultDescription
Realexposure (from PartialExposureResponseSweep)the driver being swept: a concentration, or a dose
Realfrac (from PartialExposureResponseSweep)Hill fraction, 0..1 — the shared part of every exposure-response shape
Realresponse (from PartialExposureResponseSweep)modelled response at that exposure

Revisions

  • 11/2026 generated by pharmacolibrary-dev export.pharmacolibrary_models from Ko_1995: parameters extracted from the paper by the pharmacolibrary-dev pipeline, model built by its engineer, reviewed: accepted with caveats