modelSarilumab_Ma2020_PD_anc

indirect_response_iv exposure-response sweep — Ma_2020 :: ANC (Absolute Neutrophil Count)

Extends from Pharmacolibrary.Pharmacodynamic.IndirectTurnoverSweep (steady state of an indirect-response model whose driver stimulates fractional turnover).

Information

Sarilumab_Ma2020_PD_anc

The steady-state exposure-response curve of Ma L et al., Clinical pharmacokinetics 59(11):1451–1466 2020 (doi:10.1007/s40262-020-00899-7) — Absolute Neutrophil Count [× 10^9/L] against sarilumab mg/L — obtained by sweeping the driver instead of simulating a dose. Model family: indirect_response_iv.

The parameters, in the paper's terms

  E0    =       5.38 × 10^9/L drug-free response (baseline) (BASE, Q324)
  Emax  =        1.5          maximal effect term (Emax, Q320)
  EC50  =       10.3 mg/L     exposure at half of the maximal effect term (EC50, Q321)
  gamma =      0.862          Hill coefficient (Γ, Q325)

The algebra is IndirectTurnoverSweep; this model only supplies the numbers. The x axis is one mg/L of sarilumab per second of simulated time (exposure is in kg/m3): there is no state, no dose and no kinetics — plot response against exposure (or time).

The effect term enters as a reciprocal (steady state of der(R) = Kin - Kout*(1 + Emax*frac)*R), so EC50 is the exposure at half the maximal STIMULATION of turnover, not at half the response.

What it reproduces

  exposure = 0         response 5.38   (drug-free)
  exposure = EC50 (10.3 mg/L)  response 3.074
  exposure -> infinity  response 2.152

Parameters

TypeNameDefaultDescription
RealE0 (from PartialExposureResponseSweep)0response with no drug
RealEmax (from PartialExposureResponseSweep)1maximal effect term — how it enters the response is set by the extending class
RealEC50 (from PartialExposureResponseSweep)1exposure at half of the maximal EFFECT TERM (D50, for a dose sweep)
Realgamma (from PartialExposureResponseSweep)1Hill coefficient
Realexposure_per_s (from PartialExposureResponseSweep)1.0exposure units per second of simulated time — the sweep rate

Components

TypeNameDefaultDescription
Realexposure (from PartialExposureResponseSweep)the driver being swept: a concentration, or a dose
Realfrac (from PartialExposureResponseSweep)Hill fraction, 0..1 — the shared part of every exposure-response shape
Realresponse (from PartialExposureResponseSweep)modelled response at that exposure
Realstimulation (from IndirectTurnoverSweep)the (1 + Emax*frac) turnover factor at that exposure
Realinhibition_pct (from IndirectTurnoverSweep)reduction from the drug-free baseline [%]

Revisions

  • 11/2026 generated by pharmacolibrary-dev export.pharmacolibrary_models from Ma_2020: parameters extracted from the paper by the pharmacolibrary-dev pipeline, model built by its engineer, reviewed: curated candidate