modelRitlecitinib_Wang2025_PD_eba

indirect_response_iii exposure-response sweep — Wang_2025 :: EBA (eyebrow assessment)

Extends from Pharmacolibrary.Interfaces.PartialExposureResponseSweep (static exposure-response curve in which TIME IS THE SWEEP AXIS, not time).

Information

Ritlecitinib_Wang2025_PD_eba

The steady-state exposure-response curve of Wang Y et al., CPT: pharmacometrics & systems pharmacology 14(2):389–402 2025 (doi:10.1002/psp4.13283) — eyebrow assessment against ritlecitinib ng/mL — obtained by sweeping the driver instead of simulating a dose. Model family: indirect_response_iii.

The parameters, in the paper's terms

  E0    =       6.05          drug-free response (baseline) (Baseline (B 1), Q324)
  Emax  =         11          maximal effect term (Maximum Drug effect (E max), Q320)
  EC50  =       10.6 ng/mL    exposure at half of the maximal effect term (Drug concentration producing half of the maximum stimulation (EC 50), Q321)
  gamma = (library default) Hill coefficient

The algebra is response = E0*(1 + Emax*frac); this model only supplies the numbers. The x axis is one ng/mL of ritlecitinib per second of simulated time (exposure is in kg/m3): there is no state, no dose and no kinetics — plot response against exposure (or time).

What it reproduces

  exposure = 0         response 6.05   (drug-free)
  exposure = EC50 (10.6 ng/mL)  response 39.32
  exposure -> infinity  response 72.6

Parameters

TypeNameDefaultDescription
RealE0 (from PartialExposureResponseSweep)0response with no drug
RealEmax (from PartialExposureResponseSweep)1maximal effect term — how it enters the response is set by the extending class
RealEC50 (from PartialExposureResponseSweep)1exposure at half of the maximal EFFECT TERM (D50, for a dose sweep)
Realgamma (from PartialExposureResponseSweep)1Hill coefficient
Realexposure_per_s (from PartialExposureResponseSweep)1.0exposure units per second of simulated time — the sweep rate

Components

TypeNameDefaultDescription
Realexposure (from PartialExposureResponseSweep)the driver being swept: a concentration, or a dose
Realfrac (from PartialExposureResponseSweep)Hill fraction, 0..1 — the shared part of every exposure-response shape
Realresponse (from PartialExposureResponseSweep)modelled response at that exposure

Revisions

  • 11/2026 generated by pharmacolibrary-dev export.pharmacolibrary_models from Wang_2025: parameters extracted from the paper by the pharmacolibrary-dev pipeline, model built by its engineer, reviewed: accepted with caveats