modelKetoprofen_Nixon2022_PD_pge2

indirect_response_i exposure-response sweep — Nixon_2022 :: PGE2 (interstitial fluid prostaglandin E2)

Extends from Pharmacolibrary.Pharmacodynamic.IndirectTurnoverSweep (steady state of an indirect-response model whose driver stimulates fractional turnover).

Information

Ketoprofen_Nixon2022_PD_pge2

The steady-state exposure-response curve of Nixon E et al., Journal of veterinary pharmacology and therapeutics 45(5):450–466 2022 (doi:10.1111/jvp.13083) — interstitial fluid prostaglandin E2 [% difference] against S-(+)-ketoprofen μg/ml — obtained by sweeping the driver instead of simulating a dose. Model family: indirect_response_i.

The parameters, in the paper's terms

  E0    = 88.547008547 % difference drug-free response (baseline) (kin/kout, Q327/Q328)
  Emax  =      97.33          maximal effect term (Imax, Q323)
  EC50  =       0.08 μg/ml    exposure at half of the maximal effect term (ISF IC50, Q322)
  gamma =       2.07          Hill coefficient (Gamma, Q325)

The algebra is IndirectTurnoverSweep; this model only supplies the numbers. The x axis is one μg/ml of S-(+)-ketoprofen per second of simulated time (exposure is in kg/m3): there is no state, no dose and no kinetics — plot response against exposure (or time).

The effect term enters as a reciprocal (steady state of der(R) = Kin - Kout*(1 + Emax*frac)*R), so EC50 is the exposure at half the maximal STIMULATION of turnover, not at half the response.

What it reproduces

  exposure = 0         response 88.55   (drug-free)
  exposure = EC50 (0.08 μg/ml)  response 1.783
  exposure -> infinity  response 0.9005

Parameters

TypeNameDefaultDescription
RealE0 (from PartialExposureResponseSweep)0response with no drug
RealEmax (from PartialExposureResponseSweep)1maximal effect term — how it enters the response is set by the extending class
RealEC50 (from PartialExposureResponseSweep)1exposure at half of the maximal EFFECT TERM (D50, for a dose sweep)
Realgamma (from PartialExposureResponseSweep)1Hill coefficient
Realexposure_per_s (from PartialExposureResponseSweep)1.0exposure units per second of simulated time — the sweep rate

Components

TypeNameDefaultDescription
Realexposure (from PartialExposureResponseSweep)the driver being swept: a concentration, or a dose
Realfrac (from PartialExposureResponseSweep)Hill fraction, 0..1 — the shared part of every exposure-response shape
Realresponse (from PartialExposureResponseSweep)modelled response at that exposure
Realstimulation (from IndirectTurnoverSweep)the (1 + Emax*frac) turnover factor at that exposure
Realinhibition_pct (from IndirectTurnoverSweep)reduction from the drug-free baseline [%]

Revisions

  • 11/2026 generated by pharmacolibrary-dev export.pharmacolibrary_models from Nixon_2022: parameters extracted from the paper by the pharmacolibrary-dev pipeline, model built by its engineer, reviewed: curated candidate