modelOxitriptan_Guan2020_PD_cortisol
linear exposure-response sweep — Guan_2020 :: cortisol (serum cortisol)
Extends from Pharmacolibrary.Interfaces.PartialExposureResponseSweep (static exposure-response curve in which TIME IS THE SWEEP AXIS, not time).
Information
Oxitriptan_Guan2020_PD_cortisol
The steady-state exposure-response curve of Guan Z et al., Pharmacology research & perspectives 8(2):e00574 2020 (doi:10.1002/prp2.574) — serum cortisol [ng/mL] against 5-HTP — obtained by sweeping the driver instead of simulating a dose. Model family: linear.
The parameters, in the paper's terms
E0 = 88.6 ng/mL drug-free response (baseline) (Baseline, Q324) slope = 0.072 change in response per unit of exposure (S 0, Q335)
The algebra is response = E0 + slope*exposure; this model only supplies the numbers. The x axis is one of 5-HTP per second of simulated time: there is no state, no dose and no kinetics — plot response against exposure (or time).
What it reproduces
exposure = 0 response 8.86e-05 (drug-free)
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Real | E0 (from PartialExposureResponseSweep) | 0 | response with no drug |
| Real | Emax (from PartialExposureResponseSweep) | 1 | maximal effect term — how it enters the response is set by the extending class |
| Real | EC50 (from PartialExposureResponseSweep) | 1 | exposure at half of the maximal EFFECT TERM (D50, for a dose sweep) |
| Real | gamma (from PartialExposureResponseSweep) | 1 | Hill coefficient |
| Real | exposure_per_s (from PartialExposureResponseSweep) | 1.0 | exposure units per second of simulated time — the sweep rate |
| Real | slope | 0.072 | [1] |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Real | exposure (from PartialExposureResponseSweep) | the driver being swept: a concentration, or a dose | |
| Real | frac (from PartialExposureResponseSweep) | Hill fraction, 0..1 — the shared part of every exposure-response shape | |
| Real | response (from PartialExposureResponseSweep) | modelled response at that exposure |
Revisions
- 11/2026 generated by pharmacolibrary-dev export.pharmacolibrary_models from Guan_2020: parameters extracted from the paper by the pharmacolibrary-dev pipeline, model built by its engineer, reviewed: curated candidate