modelVilanterol_Kempsford2014_PD_hr
linear exposure-response sweep — Kempsford_2014 :: HR (maximal heart rate)
Extends from Pharmacolibrary.Interfaces.PartialExposureResponseSweep (static exposure-response curve in which TIME IS THE SWEEP AXIS, not time).
Information
Vilanterol_Kempsford2014_PD_hr
The steady-state exposure-response curve of Kempsford R et al., British journal of clinical pharmacology 77(3):466-479 2014 (doi:10.1111/bcp.12243) — maximal heart rate [beats min−1] against VI pg ml−1 — obtained by sweeping the driver instead of simulating a dose. Model family: linear.
The parameters, in the paper's terms
E0 = 23.6 beats min−1 drug-free response (baseline) (Intercept, Q324) slope = 0.0173 beats min−1 pg−1 ml change in response per unit of exposure (Slope, Q335)
The algebra is response = E0 + slope*exposure; this model only supplies the numbers. The x axis is one pg ml−1 of VI per second of simulated time (exposure is in kg/m3): there is no state, no dose and no kinetics — plot response against exposure (or time).
What it reproduces
exposure = 0 response 23.6 (drug-free)
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Real | E0 (from PartialExposureResponseSweep) | 0 | response with no drug |
| Real | Emax (from PartialExposureResponseSweep) | 1 | maximal effect term — how it enters the response is set by the extending class |
| Real | EC50 (from PartialExposureResponseSweep) | 1 | exposure at half of the maximal EFFECT TERM (D50, for a dose sweep) |
| Real | gamma (from PartialExposureResponseSweep) | 1 | Hill coefficient |
| Real | exposure_per_s (from PartialExposureResponseSweep) | 1.0 | exposure units per second of simulated time — the sweep rate |
| Real | slope | 0.0173 | [beats min−1 pg−1 ml] |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Real | exposure (from PartialExposureResponseSweep) | the driver being swept: a concentration, or a dose | |
| Real | frac (from PartialExposureResponseSweep) | Hill fraction, 0..1 — the shared part of every exposure-response shape | |
| Real | response (from PartialExposureResponseSweep) | modelled response at that exposure |
Revisions
- 11/2026 generated by pharmacolibrary-dev export.pharmacolibrary_models from Kempsford_2014: parameters extracted from the paper by the pharmacolibrary-dev pipeline, model built by its engineer, reviewed: curated candidate