modelConcEffect

instant sigmoid Emax effect against a GIVEN concentration (no PK model)

Extends from Pharmacolibrary.Interfaces.PartialConcEffect (empirical concentration-response; no fitted PK model).

Information

ConcEffect

The concrete, instantiable form of PartialConcEffect — the same relation effect = E0 + Emax*conc^gamma/(EC50^gamma + conc^gamma), usable as a COMPONENT. EmaxEffect is its counterpart for a concentration arriving on a ConcentrationPort from a fitted PK model; this one takes the concentration as a plain input, for a paper that fitted effect directly against a reported concentration with no PK model anywhere.

Drive it from the enclosing model

The input must be bound where the component is used:

  model MyCurve
    Pharmacolibrary.Pharmacodynamic.ConcEffect pd(E0 = …, Emax = …, EC50 = …, gamma = …);
  equation
    pd.conc = 1.0*time;      // sweep, so the plot is effect against concentration
  end MyCurve;

A sub-component's input is a free variable of the enclosing model and can be bound by an equation. A TOP-LEVEL input cannot: extending the partial directly in a simulated model leaves conc unbound, it defaults to zero, and the model returns E0 at every point while still checking and simulating without complaint. That is the reason this concrete class exists.

Parameters

TypeNameDefaultDescription
RealE0 (from PartialConcEffect)0baseline effect (no drug)
RealEmax (from PartialConcEffect)maximal effect
RealEC50 (from PartialConcEffect)concentration at half-maximal effect
Realgamma (from PartialConcEffect)1Hill/sigmoidicity

Components

TypeNameDefaultDescription
Realconc (from PartialConcEffect)plasma/measured concentration (reported/observed by the paper, not derived from a fitted PK compartment)
Realeffect (from PartialConcEffect)