modelTissue

Extends from Physiolibrary.Icons.Microcirculation.

Information

Blood resistance in gastro interstitial tract.

Parameters

TypeNameDefaultDescription
Physiolibrary.Types.HydraulicConductanceCond
BooleanonViscositytrue
BooleanonAnesthesiatrue
BooleanonAngiogenesistrue
BooleanonAngiotensinIItrue
BooleanonVasopressintrue
BooleanonCatecholaminestrue
BooleanonOxygenOnlytrue
BooleanonOxygenAndCarbonDioxidefalse
BooleanonOxygenNeedfalse
BooleanonExercisefalse
RealVasculatureConductanceOnPO2{{41, 1.2, 0}, {51, 1.0, -0.03}, {61, 0.8, 0}}
RealPO2OnConductance{{10, 2.0, 0}, {30, 1.0, 0}}
RealAngiotensin2Effect{{0.0, 1.05, 0}, {1.3, 1.00, -0.08}, {3.5, 0.50, 0}}
RealAlphaReceptorsEffect{{0.0, 1.3, 0}, {1.0, 1.0, -0.3}, {5.0, 0.1, 0}}
RealVasopressinEffect{{0.8, 1.0, 0}, {3.0, 0.1, 0}}
Physiolibrary.Types.TimeVasculatureHalfTime30*86400*Modelica.Math.log(2)
BooleanFunctionFailedfalseFunction failed

Connectors

TypeNameDefaultDescription
Physiolibrary.Types.TissueBusConnectortissueConnector
Physiolibrary.Fluid.Interfaces.FluidPort_aport_aBlood inflow
Physiolibrary.Fluid.Interfaces.FluidPort_bport_bBlood outflow
Physiolibrary.Types.RealIO.VolumeFlowRateOutputBloodFlow
Physiolibrary.Types.BusConnectorbusConnectorsignals of organ bood flow resistence
Types.RealIO.FrequencyInputGangliaSympathetic ganglia general neural activity

Components

TypeNameDefaultDescription
Physiolibrary.Blocks.Factors.SplineA2Effect
Physiolibrary.Blocks.Factors.SplineADHEffect0.8 pg/ml = 0.8e-9 kg/m3
Physiolibrary.Types.Constants.HydraulicConductanceConstBasicConductance
Physiolibrary.Blocks.Factors.NormalizationAnesthesia
Components.ViscosityConductanceViscosity
Physiolibrary.Blocks.Factors.SplineLagOrZeroVasculature
Components.AlphaReceptorsAplhaReceptors
Physiolibrary.Fluid.Components.Conductorarterioles
Physiolibrary.Blocks.Factors.SplinepO2OnConductance
Physiolibrary.Blocks.Factors.SplineTensionEffect
Physiolibrary.Blocks.Factors.SplinePO2OnTension
Physiolibrary.Blocks.Factors.SplinePCO2OnTensionFIX: normal venous pCO2 in brain to 55mmHg (because of RQ close to 1)
Physiolibrary.Types.Constants.OneConstone
Components.MetabolicVasodilationmetabolicVasolidation
Physiolibrary.Blocks.Factors.NormalizationMusclePumping_SkeletalMuscle
Physiolibrary.Blocks.Math.Addadd
Physiolibrary.Blocks.Factors.SplineRateEffect
Physiolibrary.Blocks.Factors.SplineIntensityEffect
Physiolibrary.Types.Constants.OneConstone1
Physiolibrary.Fluid.Sensors.VolumeFlowMeasurevolumeFlowMeasure
Fluid.Sensors.Concentrationvasopressin
Fluid.Sensors.ExtraPropertyanesthesiaVascularConductance
Fluid.Sensors.PartialPressurepO2
Fluid.Components.ElasticVesselelasticVessel
Fluid.Components.Conductorvenules
Fluid.Sensors.PartialPressurepCO2
Fluid.Sensors.MassConcentrationangiotensin2
Physiolibrary.Types.HydraulicConductancecond
Modelica.Fluid.SystemsystemSystem wide properties

Contents

NameDescription
Blood

Revisions

  • january 2009
    by Marek Matejak in Modelica initially implemented (consulted with Jiri Kofranek), Charles University, Prague
    orginaly described by Tom Coleman in QHP 2008 beta 3, University of Mississippi Medical Center