modelTissue
Extends from Physiolibrary.Icons.Microcirculation.
Information
Blood resistance in gastro interstitial tract.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Physiolibrary.Types.HydraulicConductance | Cond | ||
| Boolean | onViscosity | true | |
| Boolean | onAnesthesia | true | |
| Boolean | onAngiogenesis | true | |
| Boolean | onAngiotensinII | true | |
| Boolean | onVasopressin | true | |
| Boolean | onCatecholamines | true | |
| Boolean | onOxygenOnly | true | |
| Boolean | onOxygenAndCarbonDioxide | false | |
| Boolean | onOxygenNeed | false | |
| Boolean | onExercise | false | |
| Real | VasculatureConductanceOnPO2 | {{41, 1.2, 0}, {51, 1.0, -0.03}, {61, 0.8, 0}} | |
| Real | PO2OnConductance | {{10, 2.0, 0}, {30, 1.0, 0}} | |
| Real | Angiotensin2Effect | {{0.0, 1.05, 0}, {1.3, 1.00, -0.08}, {3.5, 0.50, 0}} | |
| Real | AlphaReceptorsEffect | {{0.0, 1.3, 0}, {1.0, 1.0, -0.3}, {5.0, 0.1, 0}} | |
| Real | VasopressinEffect | {{0.8, 1.0, 0}, {3.0, 0.1, 0}} | |
| Physiolibrary.Types.Time | VasculatureHalfTime | 30*86400*Modelica.Math.log(2) | |
| Boolean | FunctionFailed | false | Function failed |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| Physiolibrary.Types.TissueBusConnector | tissueConnector | ||
| Physiolibrary.Fluid.Interfaces.FluidPort_a | port_a | Blood inflow | |
| Physiolibrary.Fluid.Interfaces.FluidPort_b | port_b | Blood outflow | |
| Physiolibrary.Types.RealIO.VolumeFlowRateOutput | BloodFlow | ||
| Physiolibrary.Types.BusConnector | busConnector | signals of organ bood flow resistence | |
| Types.RealIO.FrequencyInput | Ganglia | Sympathetic ganglia general neural activity |
Components
Contents
| Name | Description |
|---|---|
Revisions
- january 2009
by Marek Matejak in Modelica initially implemented (consulted with Jiri Kofranek), Charles University, Prague
orginaly described by Tom Coleman in QHP 2008 beta 3, University of Mississippi Medical Center