For the human body to function optimally, it is critical to hold the core temperature at 35–39°C. A fever of 41°C for more than a short period of time causes brain damage. If the core temperature falls below 10°C, the heart stops. As in the hydraulic domain, the thermal domain is simplified to these conditions.

In the Thermal package extends the package Modelica.Thermal.HeatTransfer from Modelica Standard Library 3.2 (MSL), where the connector is composed of temperature and heat flow. The main blocks in Thermal are: Conductor, IdealRadiator and HeatAccumulation. The heat conductor conducts the heat from the source, such us muscles or metabolically active tissue, to its surrounding. IdealRadiator delivers heat to tissues by blood circulation. HeatAccumulation plays a role in accumulating thermal energy in each tissue mass driven by its heat capacity. We recommend to use this block instead of Modelica.Thermal.HeatTransfer.HeatCapacitor to have possibility of variable mass amount or to have a support for calculation of steady state.

Contents

Name Description
 Examples Examples that demonstrate usage of the Pressure flow components
 Components
 Sources
 Interfaces

Revisions

Copyright (c) 2008-2015, Marek Mateják, Charles University in Prague

All rights reserved.

Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:

  1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.
  2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution.
  3. Neither the name of the copyright holder nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission.

THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.


Generated at 2021-03-05T02:00:49Z by OpenModelicaOpenModelica 1.18.0~dev-116-gde4b0c0 using GenerateDoc.mos