.Physiolibrary.Types

Information

The main problem of medical research, articles, and experiments is using obscure units from medicine, pharmacology, biology and non-physics disciplines. The Physiolibrary fulfills the Modelica ideal of using SI units as the main unit for each variable, and the previously described physiological units are also implemented as the displayUnits for each variable. Using these displayUnits the user sets and sees the "physiological" values. The implementation can also be joined to any unit-correct Modelica models and physical equations without crashing due to unit incompatibilities. The unit support of Physiolibrary is so strong that you even can chose the right unit-typed “input real”/”output real” from the library package Types.RealIO. As can be expected, only the non-specific packages States and Blocks in the Physiolibrary have variables without units.

Contents

Name Description
 UsersGuide User's Guide
 Examples Examples that demonstrate usage of the Pressure flow components
 Constants
 ScaleConstants
 RealIO
 BusConnector Empty control bus that is adapted to the signals connected to it
 IO_Bus Subsystem outputs manipulation
 TorsoBusConnector Upper, Middle or Lower Torso properties
 TissueBusConnector Tissue properties
 Energy
 Time
 Frequency
 Mass
 MassFlowRate
 Density
 MolarMass
 Height
 Position
 Velocity
 Acceleration
 Pressure
 Volume
 VolumeFlowRate
 Concentration
 AmountOfSubstance
 MolarFlowRate
 MolarEnergy
 MassConcentration
 Osmolarity
 Heat
 Temperature
 HeatFlowRate
 Power
 PowerPerMass
 ThermalConductance
 SpecificHeatCapacity
 SpecificEnergy vaporization, ..
 ElectricPotential
 ElectricCharge
 VolumeDensityOfCharge
 ElectricCurrent
 Fraction
 pH
 OsmoticPermeability
 DiffusionPermeability
 HydraulicConductance
 HydraulicResistance
 HydraulicCompliance
 HydraulicElastance
 HydraulicInertance
 GasSolubility Gas solubility in liquid
 StoichiometricNumber
 Population Average number of population individuals
 PopulationChange Average change of population individuals
 PopulationChangePerMember Average change per population individual
 AbstractReal Abstract parameter or the value at defined time (final) of the model - can be input or output parameter
 RealTypeInputParameters
 RealExtension
 RealTypes
 AbstractBoolean Abstract parameter or the value at defined time of the model - can be input or output parameter
 FilesUtilities File input/output/test
 BooleanExtension
 Utilities Value input/output/test support
 ZeroUtilities No input/output/test
 SimulationType Initialization or Steady state options (to determine model type before simulating)

Revisions

Copyright (c) 2008-2015, Marek Mateják, Charles University in Prague

All rights reserved.

Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:

  1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.
  2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution.
  3. Neither the name of the copyright holder nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission.

THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.


Generated at 2021-03-05T02:00:49Z by OpenModelicaOpenModelica 1.18.0~dev-116-gde4b0c0 using GenerateDoc.mos