modelDistributionSystemModelicaActiveLoads
Extends from DistributionSystemModelica.
Information
This model is similar to DistributionSystemModelica, but it adds active loads driven by simple linear dynamic systems, in order to introduce some states in the model.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Integer | N (from DistributionSystemModelica) | 4 | Number of segments of the primary distribution line |
| Integer | M (from DistributionSystemModelica) | N | Number of segments of each secondary distribution line |
| Real | alpha (from DistributionSystemModelica) | 2 | Distribution line oversizing factor |
| Modelica.Units.SI.Resistance | R_l (from DistributionSystemModelica) | 1 | Resistance of a single load |
| Modelica.Units.SI.Resistance | R_d2 (from DistributionSystemModelica) | R_l/(M^2*alpha) | Resistance of a secondary distribution segment |
| Modelica.Units.SI.Resistance | R_d1 (from DistributionSystemModelica) | R_l/(M^2*N^2*alpha) | Resistance of a primary distribution segment |
| Modelica.Units.SI.Voltage | V_ref (from DistributionSystemModelica) | 600 | Reference source voltage |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Electrical.Analog.Basic.Resistor[N] | primary (from DistributionSystemModelica) | Primary distribution line segments | |
| Modelica.Electrical.Analog.Basic.Resistor[N,M] | secondary (from DistributionSystemModelica) | Secondary distribution line segments | |
| Modelica.Electrical.Analog.Basic.Resistor[N,M] | load (from DistributionSystemModelica) | Individual load resistors | |
| Modelica.Electrical.Analog.Basic.Ground[N,M] | ground (from DistributionSystemModelica) | Load ground | |
| Modelica.Electrical.Analog.Basic.Ground | sourceGround (from DistributionSystemModelica) | Source ground | |
| Modelica.Electrical.Analog.Sources.RampVoltage | V_source (from DistributionSystemModelica) | Voltage source | |
| ActiveLoad[N] | activeLoad |