modelDistributionSystemModelica_N_160_M_160
Extends from Models.DistributionSystemModelica.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Integer | N (from DistributionSystemModelica) | 4 | Number of segments of the primary distribution line |
| Integer | M (from DistributionSystemModelica) | N | Number of segments of each secondary distribution line |
| Real | alpha (from DistributionSystemModelica) | 2 | Distribution line oversizing factor |
| Modelica.Units.SI.Resistance | R_l (from DistributionSystemModelica) | 1 | Resistance of a single load |
| Modelica.Units.SI.Resistance | R_d2 (from DistributionSystemModelica) | R_l/(M^2*alpha) | Resistance of a secondary distribution segment |
| Modelica.Units.SI.Resistance | R_d1 (from DistributionSystemModelica) | R_l/(M^2*N^2*alpha) | Resistance of a primary distribution segment |
| Modelica.Units.SI.Voltage | V_ref (from DistributionSystemModelica) | 600 | Reference source voltage |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Electrical.Analog.Basic.Resistor[N] | primary (from DistributionSystemModelica) | Primary distribution line segments | |
| Modelica.Electrical.Analog.Basic.Resistor[N,M] | secondary (from DistributionSystemModelica) | Secondary distribution line segments | |
| Modelica.Electrical.Analog.Basic.Resistor[N,M] | load (from DistributionSystemModelica) | Individual load resistors | |
| Modelica.Electrical.Analog.Basic.Ground[N,M] | ground (from DistributionSystemModelica) | Load ground | |
| Modelica.Electrical.Analog.Basic.Ground | sourceGround (from DistributionSystemModelica) | Source ground | |
| Modelica.Electrical.Analog.Sources.RampVoltage | V_source (from DistributionSystemModelica) | Voltage source |