modelWaterSourceWithSetPressure

Pressure-enthalpy source for simple water flows

Information

This is a model for a fluid boundary condition with fixed

  • pressure
  • specific enthalpy

Author: Kilian Link SCD
Checked by:
Protection class:
Used Dymola version:
Copyright © 2007 Siemens AG, PG EIP12. All rights reserved.

This model is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY. For details see disclaimer

Parameters

TypeNameDefaultDescription
SI.AbsolutePressurep01.01325e5Pressure
SI.SpecificEnthalpyh01e5Specific enthalpy
Booleanuse_pInfalse
Booleanuse_hInfalse

Connectors

TypeNameDefaultDescription
SiemensPower.Interfaces.FluidPort_bport
Modelica.Blocks.Interfaces.RealInputpIn
Modelica.Blocks.Interfaces.RealInputhIn

Components

TypeNameDefaultDescription
SI.AbsolutePressurep
SI.SpecificEnthalpyh
SI.SpecificEnthalpyhPortActualSpecific enthalpy

Revisions

  • December 2006 by Haiko Steuer