modelHeatTransfer_constAlpha

Extends from SiemensPower.Utilities.HeatTransfer.HeatTransferBaseClass (Base class for heat transfer correlation in terms of Nusselt number).

Information

Simple heat transfer correlation with constant heat transfer coefficient, used as default component in

Author: Kilian Link SCD
Checked by:
Protection class:
Used Dymola version:
Copyright © 2007 Siemens AG, PG EIP12. All rights reserved.

This model is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY. For details see
disclaimer

Parameters

TypeNameDefaultDescription
SI.CoefficientOfHeatTransferalpha_start (from HeatTransferBaseClass)200Start/constant value of heat transfer coefficient
RealheatingSurfaceFactor_set1.0factor for A_h
Advanced
IntegernumberOfNodes (from HeatTransferBaseClass)1Number of thermal port segments
SI.LengthlengthRe (from HeatTransferBaseClass)Characteristic length for Reynolds number
SI.LengthlengthNu (from HeatTransferBaseClass)Characteristic length for Nusselt number
Modelica.SIunits.AreaACrossFlow (from HeatTransferBaseClass)Cross flow area
SI.AreaAHeatTransfer (from HeatTransferBaseClass)Total heat transfer area
No input
SiemensPower.Utilities.Structures.FgzGeogeoFGZ (from HeatTransferBaseClass)Flue gas zone parameters
SiemensPower.Utilities.Structures.FinsgeoFins (from HeatTransferBaseClass)Fin parameters
SiemensPower.Utilities.Structures.PipeGeogeoPipe (from HeatTransferBaseClass)Tube parameters

Components

TypeNameDefaultDescription
SI.CoefficientOfHeatTransferalpha (from HeatTransferBaseClass)CoefficientOfHeatTransfer
RealheatingSurfaceFactor (from HeatTransferBaseClass)factor for AHeatTransfer
RealPsi (from HeatTransferBaseClass)crossing area shortening factor because of internals (factor for ACrossFlow)