TypeNameDefaultDescription
SI.Timet_startup720Receiver startup delay time
System location
nSI.Angle_deglon133.889Longitude (+ve East)
nSI.Angle_deglat-23.795Latitude (+ve North)
Technical data
Integern_h1Number of heliostats
SI.AreaA_h4Heliostat's Area
Realhe_av0.99Heliostat availability
Operating strategy
Booleanuse_onfalse= true to display when solar field is connected
Booleanuse_defocusfalse= true to use defocus strategy
Booleanuse_windfalse= true to use Wind-stop strategy
SI.Angleele_minfrom_deg(8)Heliostat stow deploy angle
SI.HeatFlowRateQ_design529.412Receiver design thermal power (with heat losses)
Realnu_start0.60Receiver energy start-up fraction
Realnu_min0.25Minimum receiver turndown energy fraction
Realnu_defocus1Receiver limiter energy fraction at defocus state
SI.VelocityWspd_max15Wind stow speed
Parasitic loads
SI.EnergyE_start90e3Start-up energy of a single heliostat
SI.PowerW_track0.055e3Tracking power for a single heliostat

Connectors

TypeNameDefaultDescription
Modelica.Blocks.Interfaces.BooleanOutputon
Modelica.Blocks.Interfaces.BooleanInputdefocus
Modelica.Blocks.Interfaces.RealInputWspd

Components

TypeNameDefaultDescription
Connectors.SolarPort_asolar (from Heliostats)
Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_aheat (from Heliostats)
Opticaloptical
SI.HeatFlowRateQ_raw
SI.HeatFlowRateQ_net
SI.Timet_ramp_startcurrent time of simulation when ramping starts
SI.Timet_ramp_endcurrent time of simulation when ramping starts
Realrec_ramp_fraction
SI.Angleelo
SI.Angleele
SI.Anglezen
SI.Anglezen2
SI.Angleazi
SI.EnergyE_raw
SI.EnergyE_dni
SI.EnergyE_field
SI.PowerW_loss
Realdamping
Booleanon_hf

Contents

NameDescription
Optical

Revisions

  • Alberto de la Calle:
    Released first version.