modelGenericFT

A simple Fischer–Tropsch process

Parameters

TypeNameDefaultDescription
SI.EnergyFlowRateE_sg_desEnergy flow to fischer tropsch reactor at design
SI.EnergyFlowRateE_sg_minMinimum syngas energy flow rate to start FT
Realfuel_conv_ratioConversion ratio of diesel to petrol
SI.Timet_ft_on_delay120*60Delay until FT starts
SI.Timet_ft_off_delay120*60Delay until FT shuts off
SI.Timet_ft_trans_delay120*60Transition time when the syngas supply flow changes
Integerramp_order_sgRamping filter order for syngas supply to FT
Integerramp_order_elecRamping filter order for electricity supply to FT
Integerramp_order_H2_pvRamping filter order for PV H2 supply to FT
Integerramp_order_waterRamping filter order for water supply to FT
Integerramp_order_CO2Ramping filter order for CO2 dump/release from FT
Integerramp_order_prodRamping filter order for products production from FT
Integertrans_order_sgTransitioning filter order for syngas supply to FT while FT is on
Integertrans_order_elecTransitioning filter order for electricity supply to FT while FT is on
Integertrans_order_H2_pvTransitioning filter order for PV H2 supply to FT while FT is on
Integertrans_order_waterTransitioning filter order for water supply to FT while FT is on
Integertrans_order_CO2Transitioning filter order for CO2 dump/release from FT while FT is on
Integertrans_order_prodTransitioning filter order for products production from FT while FT is on
Real[:]cvf_petrolVolumetric flow rate coefficients for petrol production in FT
Real[:]cvf_dieselVolumetric flow rate coefficients for diesel production in FT
Real[:]cwc_ftCompressor power coefficients in FT
Real[:]cwt_ftTurbine power coefficients in FT
Real[:]cwp_ftPumps power coefficients in FT
Real[:]cq_ftHeat flow coefficients in FT
Real[:]cm_H2_pvMass flow rate coefficients for H2 required from PV in FT
Real[:]cm_O2Mass flow rate coefficients for O2 produced in FT
Real[:]cm_waterMass flow rate coefficients for water required in FT
Real[:]cm_CO2_ftMass flow rate coefficients for CO2 dumped/released from FT
SI.Massm_nickel_ftFI.massNickel_ft_m_sg(m_flow_sg_des)Mass of Nickel/Aluminum Oxide catalyst required in FT at design for a three-year of operation
SI.Massm_cobalt_ftFI.massCobalt_ft_m_sg(m_flow_sg_des)Mass of Cobalt catalyst required in FT at design for a three-year of operation
SI.Massm_platinum_ftFI.massPlatinum_ft_m_sg(m_flow_sg_des)Mass of Platinum catalyst required in FT at design for a three-year of operation

Components

TypeNameDefaultDescription
SI.EnergyFlowRateE_sgSyngas energy flow rate to FT
SI.VolumeFlowRatev_flow_petrolVolumetric flow rate of petrol produced in FT
SI.VolumeFlowRatev_flow_dieselVolumetric flow rate of diesel produced in FT
SI.VolumeFlowRatev_flow_petrol_desVolumetric flow rate of petrol produced in FT at design
SI.VolumeFlowRatev_flow_diesel_desVolumetric flow rate of diesel produced in FT at design
SI.VolumeFlowRatev_flow_fuel_desVolumetric flow rate of fuel produced in FT at design
SI.PowerP_CCompressor power consumption
SI.PowerP_TTurbine power production
SI.PowerP_pumpsPumps power consumption
SI.MassFlowRatem_flow_H2_pvMass flow rate of H2 required from PV
SI.MassFlowRatem_flow_O2Mass flow rate of O2 produced in FT
SI.MassFlowRatem_flow_waterMass flow rate of water required in FT
SI.MassFlowRatem_flow_CO2Mass flow rate of CO2 dumped/released from FT
SI.EnergyFlowRateE_sg_inSyngas energy flow rate at FT
SI.MassFlowRatem_flow_sg_inMass flow rate of syngas at FT
SI.EnergyFlowRateE_sg_trans_preSyngas energy flow rate at the FT right before transition event
SI.EnergyFlowRateE_sg_trans_afterSyngas energy flow rate at the FT right after transition event
SI.MassFlowRatem_flow_sg_trans_preSyngas mass flow rate at the FT right before transition event
SI.MassFlowRatem_flow_sg_trans_afterSyngas mass flow rate at the FT right after transition event
Booleantranstrue if the syngas supply flow changes
Booleantrendture if the change is incremental and false if the change is decremental
Booleanuseful_prodtrue if energy/mass supply is converted to useful product i.e. fuel
SI.HeatFlowRateQ_flow_ftHeat flow produced in FT
SI.MassFlowRatem_flow_petrolMass flow rate of petrol
SI.MassFlowRatem_flow_dieselMass flow rate of diesel
SI.EnergyFlowRateE_flow_petrolEnergy flow rate of petrol leaving FT
SI.EnergyFlowRateE_flow_dieselEnergy flow rate of diesel leaving FT
IntegerstateFT state
SI.Timet_ft_w_nowTime of FT current warm-up event
SI.Timet_ft_w_nextTime of FT next warm-up event
SI.Timet_ft_c_nowTime of FT current cool-down event
SI.Timet_ft_c_nextTime of FT next cool-down event
SI.Timet_ft_trans_nowTime of FT current transition event
SI.Timet_ft_trans_nextTime of FT next transition event
SI.EnergyFlowRateE_sg_in_wasteSyngas energy flow rate wasted at FT
SI.MassFlowRatem_flow_sg_in_wasteMass flow rate of syngas supply wasted at FT
SI.PowerP_C_wasteCompressor power consumption wasted
SI.PowerP_pumps_wastePumps power consumption wasted
SI.MassFlowRatem_flow_H2_pv_wasteMass flow rate of H2 supply wasted
SI.MassFlowRatem_flow_water_wasteMass flow rate of water supply wasted at FT
SI.MassFlowRatem_flow_CO2_wasteMass flow rate of CO2 dumped/released from FT when the products are rubbish
SolarTherm.Utilities.Transition.Rampramp_up_sg
SolarTherm.Utilities.Transition.Rampramp_down_sg
Realfr_ramp_sgRamping transition rate for syngas supply to FT
SolarTherm.Utilities.Transition.Rampramp_up_elec
SolarTherm.Utilities.Transition.Rampramp_down_elec
Realfr_ramp_elecRamping transition rate for electricity supply to FT
SolarTherm.Utilities.Transition.Rampramp_up_H2_pv
SolarTherm.Utilities.Transition.Rampramp_down_H2_pv
Realfr_ramp_H2_pvRamping transition rate for PV H2 supply to FT
SolarTherm.Utilities.Transition.Rampramp_up_water
SolarTherm.Utilities.Transition.Rampramp_down_water
Realfr_ramp_waterRamping transition rate for water supply to FT
SolarTherm.Utilities.Transition.Rampramp_up_CO2
SolarTherm.Utilities.Transition.Rampramp_down_CO2
Realfr_ramp_CO2Ramping transition rate for CO2 dump/release from FT
SolarTherm.Utilities.Transition.Rampramp_up_prod
SolarTherm.Utilities.Transition.Rampramp_down_prod
Realfr_ramp_prodRamping transition rate for products production from FT
SolarTherm.Utilities.Transition.Ramptrans_up_sg
SolarTherm.Utilities.Transition.Ramptrans_down_sg
Realfr_trans_sgTransitioning rate for syngas supply to FT while FT is on
SolarTherm.Utilities.Transition.Ramptrans_up_elec
SolarTherm.Utilities.Transition.Ramptrans_down_elec
Realfr_trans_elecTransitioning rate for electricity supply to FT while FT is on
SolarTherm.Utilities.Transition.Ramptrans_up_H2_pv
SolarTherm.Utilities.Transition.Ramptrans_down_H2_pv
Realfr_trans_H2_pvTransitioning rate for PV H2 supply to FT while FT is on
SolarTherm.Utilities.Transition.Ramptrans_up_water
SolarTherm.Utilities.Transition.Ramptrans_down_water
Realfr_trans_waterTransition rate for water supply to FT while FT is on
SolarTherm.Utilities.Transition.Ramptrans_up_CO2
SolarTherm.Utilities.Transition.Ramptrans_down_CO2
Realfr_trans_CO2Transitioning rate for CO2 dump/release from FT while FT is on
SolarTherm.Utilities.Transition.Ramptrans_up_prod
SolarTherm.Utilities.Transition.Ramptrans_down_prod
Realfr_trans_prodTransition rate for products production from FT while FT is on
Modelica.Blocks.Logical.TimertimerTimer measuring the times that the FT is on
SI.Timetime_onTime marking when the FT starts running
SI.Timedt_onTime duration of everytime the FT is on
SI.TimetotTotal operating time of the FT
Booleanonthe FT on/off signal