modelAvgTElem

Losses at average fluid temperature

Extends from SolarTherm.Models.CSP.CRS.Receivers.Elem (Flat receiver element used to build up geometry).

Parameters

TypeNameDefaultDescription
SI.AreaA (from Elem)Area of aperture
RealabAbsorbtivity
RealemEmissivity
SI.CoefficientOfHeatTransferh_thHeat transfer coeff with env
Assumptions
BooleanallowFlowReversal (from PartialTwoPort)system.allowFlowReversal= true to allow flow reversal, false restricts to design direction (port_a -> port_b)

Connectors

TypeNameDefaultDescription
Modelica.Fluid.Interfaces.FluidPort_aport_a (from PartialTwoPort)Fluid connector a (positive design flow direction is from port_a to port_b)
Modelica.Fluid.Interfaces.FluidPort_bport_b (from PartialTwoPort)Fluid connector b (positive design flow direction is from port_a to port_b)
SolarTherm.Interfaces.Connectors.WeatherBuswbus (from Elem)

Components

TypeNameDefaultDescription
Modelica.Fluid.Systemsystem (from PartialTwoPort)System wide properties
SolarTherm.Models.CSP.CRS.Receivers.HeatedFluidhfluid (from Elem)
SI.RadiantPowerR (from Elem)Radiant power on aperture
SI.RadiantPowerR_loss (from Elem)Thermal loss
SI.HeatFlowRateQ_flow_loss (from Elem)Thermal convective loss