modelGenericStartPB

Generic power block model

Extends from SolarTherm.Models.PowerBlocks.PowerBlock (Power block model).

Parameters

TypeNameDefaultDescription
SI.Efficiencyeff_des0.5Power cycle efficiency at design
SI.HeatFlowRateQ_flow_desHeat of power block at design (max value)
SI.TemperatureT_amb_desAmbient temperature at design
Real[:]cfFraction operation factor coefficients
Real[:]caAmbient temperature factor coefficients
SI.HeatFlowRateQ_flow_disp0Min input for dispatch
SI.HeatFlowRateQ_flow_heat0Max input for heating
SI.Timet_heat0Time to heat when at max input
SI.Timet_cool3600Time for system to cool
Booleanstartup_energyt_heat > 0
SI.HeatFlowRateQ_flow_coolQ_flow_heat*t_heat/(t_heat + t_cool)
SI.EnergyE_onQ_flow_cool*t_cool

Connectors

TypeNameDefaultDescription
SolarTherm.Interfaces.Connectors.WeatherBuswbus

Components

TypeNameDefaultDescription
SI.PowerP (from PowerBlock)Electrical output power
SI.HeatFlowRateQ_flowHeat flow entering power block
SI.HeatFlowRateQ_flow_cycHeat flow to power cycle
SI.HeatFlowRateQ_flow_heat_netNet heating power
SI.EnergyE_heatEnergy used to start
Booleanon
Booleanheated