modelHeater
Extends from SolarTherm.Media.CO2.PropCO2.
Parameters
| Type | Name | Default | Description |
| Modelica.SIunits.ThermodynamicTemperature | T_high | 273.15 + 715 | Outlet temperature in Kelvin |
| Modelica.SIunits.ThermodynamicTemperature | T_amb | 273.15 + 40 | Outlet temperature in Kelvin |
Components
| Type | Name | Default | Description |
| Modelica.SIunits.HeatFlowRate | Q_heater | | heat transfer in the heater |
| MedPB.ThermodynamicState | state_a | | Thermodynamic State at the entrance |
| MedPB.ThermodynamicState | state_b | | Thermodynamic State at the outlet |
| Modelica.Fluid.Interfaces.FluidPort_a | port_a | | |
| Modelica.Fluid.Interfaces.FluidPort_b | port_b | | |
| SolarTherm.Types.SpecificExergy | ex_d | | destroyed exergy |
| Modelica.SIunits.ThermodynamicTemperature | T_real | | |
Contents
| Name | Description |
MedPB | |