modelIntercoolingCycle

Extends from SolarTherm.Media.CO2.PropCO2.

Parameters

TypeNameDefaultDescription
RealdeltaT_cooler15Approach difference of temperature at the outlet of the cooler
Modelica.SIunits.AbsolutePressurep_high200*10^5high pressure of the cycle
Modelica.SIunits.ThermodynamicTemperatureT_high715 + 273.15inlet temperature of the turbine
Modelica.SIunits.ThermodynamicTemperatureT_amb40 + 273.15ambiant temperature
RealPR2.371Pressure ratio
Modelica.SIunits.PowerP_nom10^8Nominal electrical power
Modelica.SIunits.Efficiencyeta_comp0.87Isentropic efficiency of the compressors
Modelica.SIunits.Efficiencyeta_turb0.9Isentropic efficiency of the turbine
Realgamma0.3Part of the mass flow going to the recompression directly
IntegerN_q15Number of discretization of the heat recuperators

Components

TypeNameDefaultDescription
SolarTherm.Models.PowerBlocks.sCO2Cycle.OnDesign.Heaterheater
SolarTherm.Models.PowerBlocks.sCO2Cycle.OnDesign.Turbineturbine
SolarTherm.Models.PowerBlocks.sCO2Cycle.OnDesign.Compressorcompressor1
SolarTherm.Models.PowerBlocks.sCO2Cycle.OnDesign.Compressorcompressor2
SolarTherm.Models.PowerBlocks.sCO2Cycle.OnDesign.Coolercooler1
SolarTherm.Models.PowerBlocks.sCO2Cycle.OnDesign.Coolercooler2
SolarTherm.Models.PowerBlocks.sCO2Cycle.OnDesign.HeatRecuperatorHTRecuperator
Modelica.SIunits.EfficiencyefficiencyCycle
RealE_bal_check
Realex_d_percent_compressor1First compressor exergy destruction
Realex_d_percent_compressor2Second compressor exergy destruction
Realex_d_percent_HTRecuperatorRecuperator exergy destruction
Realex_d_percent_heaterheater exergy destruction
Realex_d_percent_turbineturbine exergy destruction
Realex_d_percent_cooler1First cooler exergy destruction
Realex_d_percent_cooler2Second cooler exergy destruction
SolarTherm.Types.SpecificExergyex_d_totTotal exergy destruction
SolarTherm.Types.SpecificExergyex_in
Modelica.SIunits.Efficiencyeta_exExergetic efficiency

Contents

NameDescription
MedPB