.SolarTherm.Models.PowerBlocks.sCO2Cycle.OnDesign.HeatRecuperatorDTAve

Information

The heat recuperator is subdivised in N_q segments in order to accurately represent the CO2 properties variation.

This subdivision is based on the heat exchanged between both sides: it is even for all subdivision (Q_HX_HTR_dis). 

The closure equations are first the equality of the heat exchanged in every sub-HX and by imposing a pinch (of 5°C in general).

The conductance in each sub-HX is calculated with Q=UA*DTAverage, DTAverage being the average between the inlet and outlet delta T.

The parameters to integrate in the off-design PB are the UA_dis, which can be done with the CSV button. 

Contents

NameDescription
 MedPB

Generated at 2024-11-22T19:25:38Z by OpenModelicaOpenModelica 1.24.2 using GenerateDoc.mos