modelinterpolSimplePB

This model calculates a few off-design points as initial equation and after interpolate over them

Extends from SolarTherm.Media.CO2.PropCO2, Icons.PowerBlock.

Parameters

TypeNameDefaultDescription
SI.PowerP_nom100*10^6
SI.AbsolutePressurep_highCV.from_bar(250)
SI.AbsolutePressurep_lowCV.from_bar(80)
RealPRp_high/p_low
SI.ThermodynamicTemperatureT_highCV.from_degC(715)inlet temperature of the turbine
SI.ThermodynamicTemperatureT_HTF_in_desCV.from_degC(800)inlet temperature of the HTF
SI.ThermodynamicTemperatureT_lowCV.from_degC(45)Inlet temperature of the compressor
SI.ThermodynamicTemperatureT_amb_desCV.from_degC(20)ambient temperature at design
SI.TemperatureDifferencepinchHTR5
SI.TemperatureDifferencepinchExchT_HTF_in_des - T_high
SI.Efficiencyeta_comp0.89
SI.Efficiencyeta_turb0.93
IntegerN_exch5
IntegerN_HTR15
IntegerN_cooler15
FI.MoneyC_PBOverall cost of the power block
SI.ThermodynamicTemperatureT_HTF_out_des
MedPB.ThermodynamicStatestate_comW_out
IntegerN_points10
SI.ThermodynamicTemperatureT_high_fracpoints for which efficiency will be calculated
SI.MassFlowRatem_desmass flow rate at the outlet of the turbine
SI.PowerW_outpower at the outlet for off-design
SI.Efficiencyeta_cycle_onefficiency of the cycle
SI.Efficiencyeta_cycle_offefficiency of the cycle
SI.PowerW_comp
SI.HeatFlowRateQ_dis_exch
MedPB.ThermodynamicStatestate_cooler_out

Components

TypeNameDefaultDescription
SI.ThermodynamicTemperatureT_amb
Booleanm_supindicates if mass flow from tank is superior enough to calculate
SI.MassFlowRatem_HTF_bismass flow rate used for switching off the PB
SI.ThermodynamicTemperatureT_HTF_inInlet temperature of HTF
SI.ThermodynamicTemperatureT_HTF_outOutlet temperature of HTF
SI.ThermodynamicTemperatureTIT_CO2Turbine inlet Temperature of CO2
SI.ThermodynamicTemperatureT_CO2_in_HXCO2 temperature at the inlet of the exchanger
MedPB.ThermodynamicStatestate_CO2_HX
MedRec.ThermodynamicStatestate_HTF_HX
SI.TemperatureDifferencedeltaT_HX
Modelica.Fluid.Interfaces.FluidPort_afluid_a
Modelica.Fluid.Interfaces.FluidPort_bfluid_b
Modelica.Blocks.Interfaces.RealOutputW_netNet electric power output
SI.PowerP_coolingCooling power necessary to cool down the fluid

Contents

NameDescription
MedPB