modelGenerator

Generates power from shaft to electrical power connector

Information

This model describes the conversion between mechanical power and electrical power in an ideal synchronous generator. The frequency in the electrical connector is the e.m.f. of generator.

It is possible to consider the generator inertia in the model, by setting the parameter J > 0.

Parameters

TypeNameDefaultDescription
SI.Efficiencyeta1.0Mechanical to electric power conversion efficiency
SI.MomentOfInertiaJ0Moment of inertia
IntegernPoles2Number of electrical poles
Initialization
SI.Frequencyf_start60Start value of the electrical frequency
Assumptions › Dynamics
Modelica.Fluid.Types.DynamicsmomentumDynamicsModelica.Fluid.Types.Dynamics.DynamicFreeInitialDefault formulation of momentum balances

Connectors

TypeNameDefaultDescription
Interfaces.ElectricalPowerPort_Flowport
Modelica.Mechanics.Rotational.Interfaces.Flange_ashaft

Components

TypeNameDefaultDescription
SI.PowerQ_mechMechanical power
SI.PowerQ_elecElectrical Power
SI.PowerQ_lossInertial power Loss
SI.TorquetauTorque at shaft
SI.AngularVelocityomega_mAngular velocity of the shaft
SI.AngularVelocityomega_eAngular velocity of the e.m.f. rotating frame
SI.Conversions.NonSIunits.AngularVelocity_rpmshaft_rpmSI.Conversions.to_rpm(omega_m)Shaft rotational speed
SI.FrequencyfElectrical frequency