| SI.MassFlowRate | m_flow_steam_nominal | Units.Conversions.Functions.MassFlowRate_kg_s.from_lbm_hr(1.8e6) | |
| SI.MassFlowRate | m_flow_circulation_nominal | Units.Conversions.Functions.MassFlowRate_kg_s.from_lbm_hr(2.2e6) | |
| SI.Pressure | p_steam_nominal | Units.Conversions.Functions.Pressure_Pa.from_psi(1000) | |
| SI.Pressure | p_SG_inlet_nominal | Units.Conversions.Functions.Pressure_Pa.from_psi(1036) | |
| SI.Pressure | p_condenser_nominal | Units.Conversions.Functions.Pressure_Pa.from_inHg(2.5) | |
| SI.HeatFlowRate | Q_condenser_nominal | Units.Conversions.Functions.Power_W.from_btuhr(3.1e9) | |
| SI.Temperature | T_steam_nominal | Units.Conversions.Functions.Temperature_K.from_degF(545) | |
| SI.Temperature | T_feedwater_nominal | Units.Conversions.Functions.Temperature_K.from_degF(420) | |
| SI.Temperature | T_SG_inlet_nominal | Units.Conversions.Functions.Temperature_K.from_degF(440) | |
| Pressure |
| SI.Pressure | p_boiler_nominal | p_steam_nominal | Nominal boiler pressure |
| Modelica.SIunits.Pressure | p_start_boiler | p_boiler_nominal | Start value boiler pressure |
| Pressure drop |
| SI.PressureDifference | dp_riser_nominal | 1e5 | Nominal frictional pressure drop riser tubes |
| SI.PressureDifference | dp_feedwatervalve_nominal | 1e5 | Nominal pressure feed water valve |
| Modelica.SIunits.PressureDifference | dp_start_riser | dp_riser_nominal | Start value frictional pressure drop riser tubes |
| Flow |
| SI.MassFlowRate | m_flow_feedWater_nominal | m_flow_steam_nominal | Nominal feed water mass flow rate |
| Modelica.SIunits.MassFlowRate | m_flow_nom_circulation | m_flow_feedWater_nominal*1.1 | Nominal boiler circulation flow rate |
| Modelica.SIunits.Temperature | T_nom_feedWater | T_feedwater_nominal | Nominal feed water temperature |
| Modelica.SIunits.MassFlowRate | m_flow_start_feedWater | m_flow_feedWater_nominal | Start value feed water mass flow rate |
| Modelica.SIunits.MassFlowRate | m_flow_start_circulation | m_flow_nom_circulation | Start value boiler circulation flow rate |
| Level |
| Modelica.SIunits.Length | boiler_level_start | 0 | Level start value |
| Vapor quality |
| Modelica.SIunits.MassFraction | riser_vaporQuality_start_out | 0.83 | Riser outlet vapor quality |
| Temperature |
| Modelica.SIunits.Temperature | T_SG_water_inlet | T_SG_inlet_nominal | Steam generator inlet water temperature |