modeldata_PIPING
Extends from Icons.Record (Icon for records).
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| SI.Length | length_pumpToPHX | from_inch(240) | Distance from pump outlet to PHX inlet |
| SI.Length | length_PHXToRCTR | from_inch(684) | Distance from PHX outlet to inlet reactor tee |
| SI.Length | height_pumpToPHX | 0 | Elevation difference (pump - PHX) |
| SI.Length | height_PHXToRCTR | from_inch(324) | Elevation difference (PHX - RCTR) |
| SI.Length | D_PFL | from_inch(12) | Diameter of PFL piping |
| SI.Length | length_pumpToSHX | from_inch(96) | Distance from pump outlet to SHX inlet |
| SI.Length | length_SHXToPHX | from_inch(252) | Distance from SHX outlet to PHX inlet |
| SI.Length | length_PHXsToPump | from_inch(180) | Distance from PHX shell outlet to PCL pump |
| SI.Length | height_pumpToSHX | -from_inch(45) | Elevation difference (SHX - pump) |
| SI.Length | height_SHXToPHX | -from_inch(83) | Elevation difference (PHX - SHX) |
| SI.Length | height_PHXsToPump | from_inch(42) | Elevation difference (SHX - PHX) |
| SI.Length | D_PCL | from_inch(12) | Diameter of PCL piping |