functiondp_MFLOW_staticHead

Return mass flow rate m_flow as function of pressure loss dp, i.e., m_flow = f(dp), due to wall friction and static head

Information

Inputs

TypeNameDefaultDescription
dp_IN_conIN_conInput record for function dp_overall_MFLOW
dp_IN_varIN_varInput record for function dp_overall_MFLOW
SI.PressuredpPressure loss
SI.AbsolutePressuredp_small1Regularization of zero flow if |dp| < dp_small (dummy if use_dp_small = false)
Realg_times_height_abGravity times (Height(port_b) - Height(port_a))

Outputs

TypeNameDefaultDescription
SI.MassFlowRateM_FLOWOutput of function dp_overall_MFLOW