recordRankineNominalValues

Extends from TRANSFORM.Icons.Record (Icon for records).

Parameters

TypeNameDefaultDescription
Pressure
Modelica.SIunits.Pressurep_nom_turbine_HP_stage1_feed70e5Nominal turbine HP feed pressure
Modelica.SIunits.Pressurep_nom_turbine_HP_stage1_drain25e5Nominal turbine HP drain pressure
Modelica.SIunits.Pressurep_nom_turbine_HP_stage2_feedp_nom_turbine_HP_stage1_drainNominal turbine HP feed pressure
Modelica.SIunits.Pressurep_nom_turbine_HP_stage2_drain13e5Nominal turbine HP drain pressure
Modelica.SIunits.Pressurep_nom_turbine_LP_stage1_feed12e5Nominal turbine LP feed pressure
Modelica.SIunits.Pressurep_nom_turbine_LP_stage1_drain7e5Nominal turbine LP drain pressure
Modelica.SIunits.Pressurep_nom_turbine_LP_stage2_drain2e5Nominal turbine LP drain pressure
Modelica.SIunits.Pressurep_nom_condenser0.033e5Nominal condenser pressure
Modelica.SIunits.Pressurep_nom_feedWaterPump_drain82e5Nominal feed water pump pressure (at drain)
Modelica.SIunits.Pressurep_nom_preheater_LP1.95e5Nominal LP preheater pressure
Modelica.SIunits.Pressurep_nom_dearator6.9e5Nominal LP preheater pressure
Modelica.SIunits.Pressurep_nom_preheater_HP24.5e5Nominal HP preheater pressure
Modelica.SIunits.Pressurep_nom_preheater_HP_cooling_in77e5Nominal HP preheater cooling inlet pressure
Modelica.SIunits.Pressurep_nom_preheater_HP_cooling_out73e5Nominal HP preheater cooling outlet pressure
Modelica.SIunits.Pressurep_nom_to_SG_drain72e5Nominal drain to steam generator pressure
Temperature
Modelica.SIunits.TemperatureT_nom_turbine_HP_stage1_feed580 + 273.15Nominal turbine HP feed temperature
Modelica.SIunits.TemperatureT_nom_turbine_HP_stage1_drainMedium.saturationTemperature(p_nom_turbine_HP_stage1_drain) + 5Nominal turbine HP drain temperature
Modelica.SIunits.TemperatureT_nom_turbine_LP_stage1_feedMedium.saturationTemperature(p_nom_turbine_LP_stage1_feed) + 5Nominal turbine LP feed temperature
Modelica.SIunits.TemperatureT_nom_turbine_LP_stage1_drainMedium.saturationTemperature(p_nom_turbine_LP_stage1_drain) + 5Nominal turbine LP drain temperature
Modelica.SIunits.TemperatureT_nom_turbine_LP_stage2_drainMedium.saturationTemperature(p_nom_turbine_LP_stage2_drain) + 5Nominal turbine LP drain temperature
Modelica.SIunits.TemperatureT_nom_preheater_HP_cooling_out256 + 273.15Nominal HP preheater cooling temperrature
Flow
Modelica.SIunits.MassFlowRatem_flow_nom_turbine_HP_stage1290*0.78*3Nominal turbine HP mass flow rate
Modelica.SIunits.MassFlowRatem_flow_nom_turbine_HP_stage2245*0.78*3Nominal turbine HP mass flow rate
Modelica.SIunits.MassFlowRatem_flow_nom_turbine_LP_stage1245*0.78*3Nominal turbine IP1 mass flow rate
Modelica.SIunits.MassFlowRatem_flow_nom_turbine_LP_stage2230*0.78*3Nominal turbine LP mass flow rate
Modelica.SIunits.MassFlowRatem_flow_nom_turbine_LP_stage3200*0.78*3Nominal turbine LP2 mass flow rate
Modelica.SIunits.MassFlowRatem_flow_nom_feedWaterPump300*0.78*3Nominal feed water pump mass flow rate

Contents

NameDescription
Medium

Revisions