modeleta_Baumann
Baumann rule
Extends from TRANSFORM.Fluid.Machines.BaseClasses.WetSteamEfficiency.Partial_eta.
Information
Leyzerovich, A. 'Wet-steam Turbines for Nuclear Power Plants,' pg. 69, 2005.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| SI.Efficiency | eta_nominal (from Partial_eta) | 0.85 | Nominal efficiency due to wetness |
| SI.Efficiency | alpha | 1.0 | Baumann factor |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Units.NonDim | x_abs_in (from Partial_eta) | Inlet quality | |
| Units.NonDim | x_abs_out (from Partial_eta) | Outlet quality | |
| SI.Efficiency | eta (from Partial_eta) | Turbine efficiency due to wetness |