modeleta_Baumann

Baumann rule

Extends from TRANSFORM.Fluid.Machines.BaseClasses.WetSteamEfficiency.Partial_eta.

Information

Leyzerovich, A. 'Wet-steam Turbines for Nuclear Power Plants,' pg. 69, 2005.

Parameters

TypeNameDefaultDescription
SI.Efficiencyeta_nominal (from Partial_eta)0.85Nominal efficiency due to wetness
SI.Efficiencyalpha1.0Baumann factor

Components

TypeNameDefaultDescription
Units.NonDimx_abs_in (from Partial_eta)Inlet quality
Units.NonDimx_abs_out (from Partial_eta)Outlet quality
SI.Efficiencyeta (from Partial_eta)Turbine efficiency due to wetness