modelMechanicalPump

Extends from TRANSFORM.Icons.Example (Icon for runnable examples).

Information

The model is designed to test the component PumpMech. The simple model of a DC motor Test.SimpleMotor is also used.
The simulation starts with a stopped motor and a closed valve.

  • t=2 s: The voltage supplied is increased up to 380V in 5 s.
  • t=15 s, The valve is opened in 5 s.

Simulation Interval = [0...25] sec
Integration Algorithm = DASSL
Algorithm Tolerance = 1e-6

Components

TypeNameDefaultDescription
Pump_wShaftPump
BoundaryConditions.Boundary_phSource
Modelica.Blocks.Sources.RampRamp1
BoundaryConditions.Boundary_phSink
Modelica.Blocks.Sources.RampRamp2380,0.01
Mechanics.SimpleMotorSimpleMotor1
Systemsystem
FittingsAndResistances.SpecifiedResistanceValveLin1

Revisions