modelMechanicalPump
Extends from TRANSFORM.Icons.Example (Icon for runnable examples).
Information
The model is designed to test the component PumpMech. The simple model of a DC motor Test.SimpleMotor is also used.
The simulation starts with a stopped motor and a closed valve.
- t=2 s: The voltage supplied is increased up to 380V in 5 s.
- t=15 s, The valve is opened in 5 s.
Simulation Interval = [0...25] sec
Integration Algorithm = DASSL
Algorithm Tolerance = 1e-6
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Pump_wShaft | Pump | ||
| BoundaryConditions.Boundary_ph | Source | ||
| Modelica.Blocks.Sources.Ramp | Ramp1 | ||
| BoundaryConditions.Boundary_ph | Sink | ||
| Modelica.Blocks.Sources.Ramp | Ramp2 | 380,0.01 | |
| Mechanics.SimpleMotor | SimpleMotor1 | ||
| System | system | ||
| FittingsAndResistances.SpecifiedResistance | ValveLin1 |
Revisions
- 5 Nov 2005
by Francesco
Casella:
Updated. - 5 Feb 2004 by Francesco Schiavo:
First release.