.TRANSFORM.Fluid.Pipes_Obsolete.ClosureModels.HeatTransfer.Models.SinglePhase.LiquidMetal.TubeBundle.GraberRieger

Graber-Rieger: Liquid metal rod bundle; 1.25 <= P/D <= 1.95, 150 <= Pe <= 3000

Information

The Graber-Rieger is a liquid metal rod bundle heat transfer correlation.

The correlation was taken from the following textbook:

AlanE. Waltar, Donald R. Todd, Pavel V. Tsvetkov

Fast Spectrum Reactors 2012

eq. 9.34 pg. 257

and is reported valid for: