functionNu_GraberRieger
Information
The Graber-Rieger is a liquid metal rod bundle heat transfer correlation.
Range of Validity:
- liquid metal coolant
- 150 <= Pe <= 3000
- 1.25 < Pitch/Diameter <= 1.95
References
- AlanE. Waltar, Donald R. Todd, Pavel V. Tsvetkov, Fast Spectrum Reactors 2012
Inputs
| Type | Name | Default | Description |
|---|---|---|---|
| SI.ReynoldsNumber | Re | Reynolds number | |
| SI.PrandtlNumber | Pr | Prandtl number | |
| Real | PDratio | Tube Pitch to Diameter ratio |
Outputs
| Type | Name | Default | Description |
|---|---|---|---|
| SI.NusseltNumber | Nu | Nusselt number - S1:Eq. 9.34 |