Dittus-Boelter's correlation for the computation of the heat transfer coefficient in one-phase flows.
function Nu_DittusBoelter input SI.ReynoldsNumber Re "Reynolds number"; input SI.PrandtlNumber Pr "Prandtl number"; input Real A = 0.023 "Multiplication value"; input Real alpha = 0.8 "Exponent to Reynolds number"; input Real beta = 0.4 "Exponent to Prandtl number"; output SI.NusseltNumber Nu "Nusselt number"; end Nu_DittusBoelter;