modelAbsSchottSopo
Information
It solves the 1D radial energy balance around the Heat Collector Element of a solar collector based on a correlation derived in
F. Burkholder and C. Klutscher Heat loss Testing of Schott's 2008 PTR70 Parabolic Trough Receiver. Technical report. NREL May 2009
Modelling options
- Geometry: It allows to choose between the Schott PTR70 receiver and the Sopogy micro receiver - Soponova (http://www.sopogy.com).
Components
| Type | Name | Default | Description |
| Modelica.SIunits.Temperature[N] | T_fluid | | temperature of the fluid |
| Modelica.SIunits.HeatFlowRate | Q_tube_tot | | |
| Real[N] | HL | | Heat losses per meter |
| Modelica.SIunits.HeatFlux[N] | Phi_tube_tot | | Heat flux to the tube |
| Modelica.SIunits.HeatFlux[N] | Phi_conv_f | | Heat flux to the fluid |
| Modelica.SIunits.HeatFlux[N] | Phi_loss_tube | | Heat flux loss per tube surface |
| Modelica.SIunits.HeatFlux[N] | Phi_loss_ref | | Heat flux loss per reflector surface |
| Modelica.SIunits.HeatFlux | Phi_loss_ref_m | | Medium heat flux loss per reflector surface |
| Real | eta_opt | | |
| Real | eta_opt_t | | |
| Real | IAM | | Incident Angle Modifier |
| Real[N] | eta_th | | Thermal efficiency at each node |
| Real[N] | eta_TOT | | Total efficiency : eta_th * eta_opt_t |
| Real | Eta_th | | Average thermal efficiency |
| Real | Eta_TOT | | Total Average efficiency |