modelAbsSoltigua

Information

It solves the 1D radial energy balance around the Heat Collector Element of the Soltigua PTMx parabolic trough solar collector based on the Soltigua data sheet (see http://www.soltigua.com.)

The model allows to defocusing the collectors based on the Internal focusing signal. TRUE Defocusing = 0, FALSE Defocusing =1

Modelling options

  • Geometry: It allows to choose one of the different PTMx model.

Parameters

TypeNameDefaultDescription
RealSigmaModelica.Constants.sigmaStefan-Boltzmann constant
RealggModelica.Constants.g_nStandard acceleration of gravity on earth
ThermoCycle.Components.HeatFlow.Walls.SolarAbsorber.Geometry.Soltigua.BaseGeometrygeometry
IntegerN2number of cells
Modelica.SIunits.Lengthllgeometry.L/(N - 1)Length of each cell

Connectors

TypeNameDefaultDescription
ThermoCycle.Interfaces.HeatTransfer.ThermalPortwall_int
Modelica.Blocks.Interfaces.RealInputv_wind
Modelica.Blocks.Interfaces.RealInputThetaIn Radiants
Modelica.Blocks.Interfaces.RealInputDNI
Modelica.Blocks.Interfaces.RealInputTamb
Modelica.Blocks.Interfaces.IntegerInputFocusingInternal focusing signal. TRUE Defocusing = 0, FALSE Defocusing =1

Components

TypeNameDefaultDescription
Modelica.SIunits.AreaS_effeffective collecting area - Depend on focusing
RealK_lLongitudinal Incident Angle Modifier (IAM)
RealTheta_deg
Modelica.SIunits.Temperature[N]T_fluidTemperature of the fluid
Modelica.SIunits.HeatFlowRateQ_tube_totTotal thermal energy on the
Modelica.SIunits.HeatFlux[N]Phi_conv_fHeat flux to the fluid
Real[N]Eta_tot_NEfficiency based on Soltigua data sheet
RealEta_totAveraged overall Efficiency