modelPdrop

Valve assuming a linear dependency between Mdot and DELTAp

Extends from ThermoCycle.Icons.Water.PressDrop.

Information

This very simple model assumes a non-compressible flow for computing the pressure drop

Parameters

TypeNameDefaultDescription
PressureDropsDPtypePressureDrops.UD
Modelica.SIunits.MassFlowRateMdot_max0.1maximum flow rate with valve fully open at DELTAp_max
Modelica.SIunits.PressureDELTAp_max20E5
Initialization
Modelica.SIunits.Pressurep_su_start1e5Inlet pressure start value
Modelica.SIunits.PressureDELTAp_start10000Start value for the pressure drop
Modelica.SIunits.MassFlowRateMdot_start0.1Mass flow rate intial value

Components

TypeNameDefaultDescription
Modelica.SIunits.MassFlowRateMdot
Modelica.SIunits.PressureDELTAp
Interfaces.Fluid.FlangeAInFlow
Interfaces.Fluid.FlangeBOutFlow

Contents

NameDescription
Medium