modelGasTurbineSimplified
Extends from ThermoPower.PowerPlants.GasTurbine.Interfaces.GasTurbineSimplified.
Parameters
| Type | Name | Default | Description |
| Modelica.SIunits.Power | maxPower | 235e6 | |
| Modelica.SIunits.MassFlowRate | flueGasNomFlowRate | 614 | Nominal flue gas flow rate |
| Modelica.SIunits.MassFlowRate | flueGasMinFlowRate | 454 | Minimum flue gas flow rate |
| Modelica.SIunits.MassFlowRate | flueGasOffFlowRate | flueGasMinFlowRate/100 | Flue gas flow rate with GT switched off |
| Modelica.SIunits.MassFlowRate | fuelNomFlowRate | 12.1 | Nominal fuel flow rate |
| Modelica.SIunits.MassFlowRate | fuelIntFlowRate | 7.08 | Intermediate fuel flow rate |
| Modelica.SIunits.MassFlowRate | fuelMinFlowRate | 4.58 | Minimum fuel flow rate |
| Modelica.SIunits.MassFlowRate | fuelOffFlowRate | 0.1 | Flue gas flow rate with GT switched off |
| Real | constTempLoad | 0.60 | Fraction of load from which the temperature is kept constant |
| Real | intLoad | 0.42 | Intermediate load for fuel consumption computations |
| Modelica.SIunits.Temperature | flueGasNomTemp | 843 | Maximum flue gas temperature |
| Modelica.SIunits.Temperature | flueGasMinTemp | 548 | Minimum flue gas temperature (zero electrical load) |
| Modelica.SIunits.Temperature | flueGasOffTemp | 363.15 | Flue gas temperature with GT switched off |
| Modelica.SIunits.SpecificEnthalpy | fuel_LHV | 49e6 | Fuel Lower Heating Value |
| Modelica.SIunits.SpecificEnthalpy | fuel_HHV | 55e6 | Fuel Higher Heating Value |
Components
| Type | Name | Default | Description |
| FlueGasMedium.BaseProperties | gas | | |
| Modelica.SIunits.MassFlowRate | w | | |
| Modelica.SIunits.Power | P_el | noEvent(if GTLoad > 0 then GTLoad*maxPower else 0) | Electrical power output |
| Modelica.SIunits.MassFlowRate | fuelFlowRate | | Fuel flow rate |