modelTestFlow1Dd

Test case for Flow1D

Information

The model is designed to test the component Flow1D (fluid side of a heat exchanger, finite volumes).
This model is designed to the test compressibility effects. The operating fluid is superheated vapour; the heat flow entering the heat exchanger is set to zero.
During simulation mass flow rate changes:

  • t=2 s, Step variation of the inlet mass flow rate. The pressure increases with a first order dynamics, the tube actually behaving like a pressurized tank.

Simulation Interval = [0...2] sec
Integration Algorithm = DASSL
Algorithm Tolerance = 1e-6

Parameters

TypeNameDefaultDescription
IntegerNnodes20
Modelica.SIunits.LengthLhex10
Modelica.SIunits.DiameterDihex0.02
Modelica.SIunits.RadiusrhexDihex/2
Modelica.SIunits.LengthomegahexModelica.Constants.pi*Dihex
Modelica.SIunits.AreaAhexModelica.Constants.pi*rhex^2
RealCfhex0.005
Modelica.SIunits.MassFlowRatewhex1e-2
Modelica.SIunits.Pressurephex0.2e5
Modelica.SIunits.SpecificEnthalpyhs3e6

Components

TypeNameDefaultDescription
SI.Timetau
Water.Flow1Dhex
ThermoPower.Water.SourceMassFlowMassFlowRateSource
ThermoPower.Water.SinkPressureFluidSink
ThermoPower.Water.ValveLinValveLin1
Modelica.Blocks.Sources.StepMassFlowRateStep
Modelica.Blocks.Sources.ConstantConstant1
ThermoPower.Thermal.HeatSource1DHeatSource1D1
Modelica.Blocks.Sources.ConstantExtPower
Water.SensPSensP
Systemsystem

Contents

NameDescription
Medium

Revisions