.ThermoPower.Test.DistributedParameterComponents.OldTests.TestFlow1De

Information

The model is designed to test the component Flow1D (fluid side of a heat exchanger, model uses finite volumes).
This model represent the two fluid sides of a heat exchanger in counterflow configuration. The operating fluid is liquid water.
The mass flow rate during the experiment and initial conditions are the same for the two sides.
During the simulation, the inlet specific enthalpy for hexA ("hot side") is changed:

The outlet temperature of the hot side starts changing after the fluid transport time delay, while the outlet temperature of the cold side starts changing immediately.

Simulation Interval = [0...900] sec
Integration Algorithm = DASSL
Algorithm Tolerance = 1e-6

Contents

NameDescription
 Medium

Revisions