Test case for Flow1DFV2ph
The model is designed to test the component
Flow1D2ph when used as an evaporator.
This model represent the fluid side of a once-through boiler
with an applied external heat flow. The operating fluid is
water.
During the simulation, the inlet specific enthalpy and heat flux
are changed, while maintaining the inlet flowrate constant:
- t=0 s. The initial state of the water is subcooled liquid.
- t=10 s. Ramp increase of the applied heat flow. The water
starts boiling and is blown out of the outlet, whose pressure and
flowrate undergo a transient increase. At the end of the transient
the outlet fluid is in superheated vapour state.
- t=100 s. Step increase of the inlet enthalpy
- t=150 s. The heat flow is brought back to zero. The vapour
collapses, causing a suddend decrease in the outlet pressure and
flowrate, until the liquid fills again the entire boiler. At that
instant, the flowrate rises again rapidly to the inlet values.
Simulation Interval = [0...250] sec
Integration Algorithm = DASSL
Algorithm Tolerance = 1e-9
Contents
Generated at 2026-04-02T18:18:35Z by OpenModelicaOpenModelica 1.26.3 using
GenerateDoc.mos