.ThermoPower.Test.WaterComponents.TestCoeffValve

Information

This model tests the ValveLiq models with four possible flow coefficients (also applies to other valves).

  1. Av (metric) flow coefficient [m2];
  2. Kv (metric) flow coefficient [m3/h];
  3. Cv (US) flow coefficient [USG/min];
  4. Av defined by nominal operating point [m2].

Simulate the model for 4 s and observe the flowrate through the valves.

Revisions