modelTestValves
Test cases for valves
Extends from Modelica.Icons.Example (Icon for runnable examples).
Information
This model tests the ValveLiq model zero or reverse flow conditions.
Simulate the model for 4 s. At t = 1 s the V5 valve closes in 1 s, the V2 and V3 valves close in 2 s and the V1 and V4 valves open in 2 s. The flow in valve V3 reverses between t = 1.83 and t = 1.93.
Components
| Type | Name | Default | Description |
|---|---|---|---|
| ThermoPower.Water.SourcePressure | SourceP1 | ||
| ThermoPower.Water.SourcePressure | SourceP2 | ||
| ThermoPower.Water.SinkPressure | SinkP1 | ||
| ThermoPower.Water.ValveLiq | V1 | ||
| Water.ValveLiq | V2 | ||
| ThermoPower.Water.ValveLiq | V3 | ||
| ThermoPower.Water.ValveLiq | V4 | ||
| ThermoPower.Water.ValveLiq | V5 | ||
| ThermoPower.Water.SinkPressure | SinkP2 | ||
| ThermoPower.Water.SinkPressure | SinkP3 | ||
| Modelica.Blocks.Sources.Ramp | CloseLoad | ||
| Modelica.Blocks.Sources.Ramp | OpenRelief | ||
| Modelica.Blocks.Sources.Ramp | CloseValves | ||
| System | system |
Revisions
- 18 Nov 2003
by Francesco
Casella:
Parameters updated. - 1 Oct 2003
by Francesco
Casella:
First release.