modelFuelSourcePQ

Fuel source with fixed pressure and mass flow rate

Information

## Copyright © EDF 2002 - 2026  
## ThermoSysPro Version 4.2

Parameters

TypeNameDefaultDescription
Units.SI.AbsolutePressureP01e5Fuel pressure (active if pressure input port is not connected)
Units.SI.MassFlowRateQ010Fuel mass flow rate (active if mass flow input port is not connected)
Units.SI.TemperatureT0300Fuel temperature
Units.SI.SpecificEnergyLHV48e6Lower heating value
Units.SI.SpecificHeatCapacityCp1e3Fuel specific heat capacity at 273.15K
RealHum0.0Fuel humidity (%)
RealXc0.75C mass fraction
RealXh0.25H mass fraction
RealXo0O mass fraction
RealXn0N mass fraction
RealXs0S mass fraction
RealXashes0Ashes mass fraction
RealVol0Volatile matter mass fraction
Units.SI.Densityrho0.72Fuel density

Connectors

TypeNameDefaultDescription
Connectors.FuelOutletC
ThermoSysPro.InstrumentationAndControl.Connectors.InputRealIMassFlow
InstrumentationAndControl.Connectors.InputRealIPressure

Revisions

Author  

Baligh El Hefni