modelGridFurnace

Combustion furnace

Information

## Copyright © EDF 2002 - 2026  
## ThermoSysPro Version 4.2

Parameters

TypeNameDefaultDescription
RealX2eap0.1Primary air fraction in zone 2
RealX3eap0.1Primary air fraction in zone 3
RealXCleom0Cl mass fraction in the biomass
RealXFeom0F mass fraction in the biomass
RealXMACHeom0machefers mass fraction in the biomass
Units.SI.DensityrhoCENDom0.5Density of the ashes in the biomass
Units.SI.TemperatureTfrecirc600Temperature of the recirculated flue gases
RealXfCO2recirc0.3CO2 mass fraction in the recirculated flue gases
RealXfH2Orecirc0.1H2O mass fraction in the recirculated flue gases
RealXfO2recirc0.2O2 mass fraction in the recirculated flue gases
RealXfSO2recirc0SO2 mass fraction in the recirculated flue gases
RealXrecirc0.1Recirculated flue gases fraction in Qsf
Units.SI.SpecificHeatCapacityCpMACH500Clinker average specific heat capacity
Units.SI.SpecificHeatCapacityCpMACHs2500Clinker specific heat capacity at the outlet of zone 2
Units.SI.SpecificHeatCapacityCpMACHs3500Clinker specific heat capacity at the outlet of zone 3
Units.SI.SpecificHeatCapacityCpMACHs4500Clinker specific heat capacity at the outlet of zone 4
Units.SI.TemperatureTsjeMACH293Clinker temperature at the outlet of the water seal
Units.SI.TemperatureTeeje293Water temperature at the outlet of the water seal
RealXsjeH2OMACH0.2Clinker humidity at the outlet of the water seal
Realrendje1Water seal efficiency
Integerjointeau01: with water seal - 0: without water seal
RealXCvol0Volatile carbon fraction
RealXCimb0Unburnt carbon fraction
Units.SI.TemperatureT1sfm500Flue gases temperature at the outlet of zone 1
RealEray20.1Energy fraction radiated towards zone 2 of the furnace
RealEray50.1Energy fraction radiated towards zone 5 of the furnac
Realperte0Loss percent of LHV
Units.SI.SpecificHeatCapacityCp3CO500CO specific heat capacity in zone 3
Units.SI.SpecificHeatCapacityCp3g1100Average flue gases specific heat capacity at T3g
Units.SI.SpecificEnthalpyHvapo2501600Vaporisation energy

Connectors

TypeNameDefaultDescription
ThermoSysPro.FlueGases.Connectors.FlueGasesInletCa2
ThermoSysPro.Combustion.Connectors.FuelInletCom
ThermoSysPro.WaterSteam.Connectors.FluidInletport_eau_refroid
ThermoSysPro.FlueGases.Connectors.FlueGasesInletCa1
ThermoSysPro.FlueGases.Connectors.FlueGasesOutletCfgFlue gases outlet

Components

TypeNameDefaultDescription
Units.SI.MassFlowRateQsfFlue gases mass flow rate at the outlet
Units.SI.AbsolutePressurePsfFlue gases pressure at the outlet
Units.SI.TemperatureTsfFlue gases temperature at the outlet
RealXsfN2Flue gases N2 mass fraction at the outlet
RealXsfCO2Flue gases CO2 mass fraction at the outlet
RealXsfH2OFlue gases H2O mass fraction at the outlet
RealXsfO2Flue gases O2 mass fraction at the outlet
RealXsfSO2Flue gases SO2 mass fraction at the outlet
Units.SI.MassFlowRateQeapPrimary air mass flow rate
Units.SI.AbsolutePressurePeapPrimary air pressure
Units.SI.TemperatureTeapPrimary air temperature
RealXeapN2Primary air N2 mass fraction
RealXeapCO2Primary air CO2 mass fraction
RealXeapH2OPrimary air H2O mass fraction
RealXeapO2Primary air O2 mass fraction
RealXeapSO2Primary air SO2 mass fraction
Units.SI.MassFlowRateQeasSecondary air mass flow rate
Units.SI.AbsolutePressurePeasSecondary air pressure
Units.SI.TemperatureTeasSecondary air temperature
RealXeasN2Secondary air N2 mass fraction
RealXeasCO2Secondary air CO2 mass fraction
RealXeasH2OSecondary air H2O mass fraction
RealXeasO2Secondaryr O2 mass fraction
RealXeasSO2Secondary SO2 mass fraction
Units.SI.MassFlowRateQeomBiomass mass flow rate
Units.SI.TemperatureTeomBiomass temperature
RealPCIomBiomass LHV (J/kg)
RealXCeomBiomass C mass fraction
RealXHeomBiomass H mass fraction
RealXOeomBiomass O mass fraction
RealXNeomBiomass N mass fraction
RealXSeomBiomass S mass fraction
RealXCENDeomBiomass ashes mass fraction
RealXH2OeomBiomass humidity
Units.SI.SpecificHeatCapacityCpomBiomass specific heat capacity
Units.SI.MassFlowRateQerefoCooling water mass flow rate
Units.SI.SpecificEnthalpyHerefoCooling water specific enthalpy
Units.SI.MassFlowRateQfrecircRecirculated flue gases mass flow rate
RealXsfN2recircRecirculated flue gases N2 mass fraction
RealPCIMACHClinker LHV
Units.SI.MassFlowRateQsMACHClinker mass flow rate
Units.SI.TemperatureTsMACHClinket temperature
RealFVNVolatile ashes mass fraction
Units.SI.DensityrhocendAshes density in the flue gases
Units.SI.PowerWsrRadiated power
RealexcairCombustion excess air
RealX1eapPrimary air fraction in zone 1
Units.SI.MassFlowRateQ1eapPrimary mass flow rate in zone 1
Units.SI.MassFlowRateQ2eapPrimary mass flow rate in zone 2
Units.SI.MassFlowRateQ3eapPrimary mass flow rate in zone 3
RealXCvol2C mass fraction burnt in zone 2
RealXMACHimbC mass raction unburnt in the clinker
RealXCvol3C mass fraction burnt in zone 3
Units.SI.SpecificEnthalpyHeapHumid air specific enthalpy at the primary air temperature
Units.SI.SpecificEnthalpyHeasHumid air specific enthalpy at the secondary air temperature
Units.SI.SpecificEnthalpyH1aPrimary air specific enthalpy at T1sfm
Units.SI.SpecificEnthalpyHefrecircSpecific enthalpy of the incoming recirculated flue gases
Units.SI.MassFlowRateQeasmMass flow rate of the secondary air / recirculated flue gases mixture
Units.SI.SpecificEnthalpyHeasmSpecific enthalpy of the secondary air / recirculated flue gases mixture
Units.SI.TemperatureTeasmTemperature of the secondary air / recirculated flue gases mixture
RealXeasmO2O2 mass fraction in the secondary air / recirculated flue gases mixture
RealXeasmCO2CO2 mass fraction in the secondary air / recirculated flue gases mixture
RealXeasmH2OH2O mass fraction in the secondary air / recirculated flue gases mixture
RealXeasmSO2SO2 mass fraction in the secondary air / recirculated flue gases mixture
RealXeasmN2N2 mass fraction in the secondary air / recirculated flue gases mixture
Integermode0IF97 region. 1:liquid - 2:steam - 4:saturation line - 0:automatic
Units.SI.SpecificEnthalpyHeauomBiomass water specific enthalpy
Units.SI.AbsolutePressurePsateomWater saturation presure at Teom
Units.SI.SpecificEnthalpyHvteomSteam saturation specific enthalpy at Teom
Units.SI.SpecificEnthalpyHlteomWater saturation specific enthalpy at Teom
Units.SI.SpecificEnthalpyHvapteomPhase transition energy at Teom
Units.SI.SpecificEnthalpyHs1vomWater specific enthalpy of the outgoing biomass at T1sfm vapor
Units.SI.SpecificEnthalpyHeomBiomass specific enthalpy at the inlet
Units.SI.PowerWffFlue gases formation energy
Units.SI.PowerWpBiomass pyrolysis power
Units.SI.PowerWimbpPower saved in the combustion flue gases due to the non-destruction of unburnt C
Units.SI.PowerWimbmPower lost by the combustion flue gases due to the non-combustion of unburnt C
Units.SI.SpecificEnthalpyHpyrPyrolysis specific enthalpy
Units.SI.SpecificEnthalpyH1omSpecific enthalpy of the dry biomass at the pyrolysis temperature of the biomass
Units.SI.MassFlowRateQ1H2OH2O mass flow rate at the oultet of zone 1
Units.SI.MassFlowRateQ1O2O2 mass flow rate at the oultet of zone 1
Units.SI.MassFlowRateQ1N2N2 mass flow rate at the oultet of zone 1
Units.SI.MassFlowRateQ1CO2CO2 mass flow rate at the oultet of zone 1
Units.SI.MassFlowRateQ1SO2SO2 mass flow rate at the oultet of zone 1
Units.SI.MassFlowRateQ1gTotal mass flow rate at the oultet of zone 1
Units.SI.MassFlowRateQ2eomBiomass mass flow rate at the inlet of zone 2
RealPCI1omLHV after drying
RealX1MACHomClinker mass fraction in the biomass after drying
RealXC1vol2Burnt C mass fraction in zone 2 after drying
RealXC1vol3Burnt C mass fraction in zone 3 after drying
RealX1MACHimbUnburnt C mass fraction in the clinker after drying
RealX1HH mass fraction in the biomass after drying
RealX1OO mass fraction in the biomass after drying
RealX1NN mass fraction in the biomass after drying
RealX1ClCl mass fraction in the biomass after drying
RealX1FF mass fraction in the biomass after drying
RealX1SS mass fraction in the biomass after drying
RealX1CENDAshes mass fraction in the biomass after drying
Units.SI.MassFlowRateQcendomAshes mass flow rate
RealXfcendAshes mass fraction in the flue gases
Units.SI.PowerP1gPower saved in zone 1
Units.SI.MassFlowRateQ2eoMass flow rate of the oxygen carried by the air and the biomass at the inlet of zone 2
Units.SI.MassFlowRateQ2HClCombustion HCl mass fraction in zone 2
Units.SI.MassFlowRateQ2HFCombustion HF mass flow rate at the outlet of zone 2
Units.SI.MassFlowRateQ2SO2Combustion SO2 mass flow rate at the outlet of zone 2
Units.SI.MassFlowRateQ2H2OCombustion H2O mass flow rate at the outlet of zone 2
Units.SI.MassFlowRateQ2COCombustion CO mass flow rate at the outlet of zone 2
Units.SI.MassFlowRateQ2N2Combustion N2 mass flow rate at the outlet of zone 2
Units.SI.MassFlowRateQ2O2Combustion O2 mass flow rate at the outlet of zone 2
Units.SI.MassFlowRateQ2cendCombustion ashes mass flow rate at the outlet of zone 2
Units.SI.MassFlowRateQ2CO2Combustion CO2 mass flow rate at the outlet of zone 2
Units.SI.MassFlowRateQ2gElements total mass flow rate after combustion
RealEpsivolVolatile matter mass fraction produced in zone 2
Units.SI.MassFlowRateQ3eomSolid matter at the inlet of zone 3
RealX2MACHomClinker mass fraction of the biomass after volatilisation
RealXC2vol3C mass fraction burnt in zone 3 after volatilisation
RealX2MACHimbUnburnt C mas fraction in the clinker after volatilisation
RealPCICsolLHV of the solid outgoing carbon
RealPCICvolLHV of the volatile carbon transformed into CO
Units.SI.SpecificEnthalpyH2Enthalpy released in zone 2
Units.SI.PowerP2gPower released by the combustion in zone 2
Units.SI.PowerP1oPower captured by the biomass
Units.SI.PowerP1vPower captured by the steam
Units.SI.PowerP1aPower captured by the air
Units.SI.PowerP1rPower captured by the cooling water
RealEray0Fraction of the radiated power from zone 2 unused for the drying
RealX2O2O2 mass fraction at the oultet of zone 2
RealX2SO2SO2 mass fraction at the oultet of zone 2
RealX2CO2CO2 mass fraction at the oultet of zone 2
RealX2H2OH2O mass fraction at the oultet of zone 2
RealX2N2N2 mass fraction at the oultet of zone 2
Units.SI.SpecificEnthalpyH2gFlue gases specific enthalpy at the oultet of zone 2
Units.SI.TemperatureT2Flue gases temperature at the oultet of zone 2
Units.SI.MassFlowRateQ3odO mass flow rate available for the oxydation of the clinker in CO and/or CO2
Units.SI.MassFlowRateQ3cdC mass flow rate available for the oxydation of the clinker in CO and/or CO2
Realtaux3ocRatio of the mass flow rates O/C available for the oxydation of the clinker
Units.SI.MassFlowRateQ3CO2CO2 mass flow rate at the outlet of zone 3
Units.SI.MassFlowRateQ3COCO mass flow rate at the outlet of zone 3
Units.SI.MassFlowRateQ3O2O2 mass flow rate at the outlet of zone 3
Units.SI.MassFlowRateQ3N2N2 mass flow rate at the outlet of zone 3
Units.SI.MassFlowRateQ3H2OH2O mass flow rate at the outlet of zone 3
Units.SI.MassFlowRateQ3SO2SO2 mass flow rate at the outlet of zone 3
Units.SI.PowerP3sPower captured by solid matter in zone 3
Units.SI.PowerP3gPower captured by gaseous matter in zone 3
Units.SI.SpecificEnthalpyH3sGaseous matter specific enthalpy at T3g
Units.SI.SpecificEnthalpyH3gSolid matter specific enthalpy at T3o
RealXC2vol31C mass fraction burnt in zone 3 after volatilisation
RealXC2vol4C mass fraction burnt at the inlet of zone 4
Units.SI.MassFlowRateQ3gFlue gases mass flow rate at the outlet of zone 3
Units.SI.MassFlowRateQ4eomClinker mass flow rate at the inlet of zone 4
RealX4MACHomMass flow rate of the biomass clinker after C volatilisation in zone 3
RealX4MACHimbUnburnt C mass fraction in the clinker after C volatilisation in zone 3
Units.SI.SpecificHeatCapacityCp3aAverage specific heat capacity at the inlet of zone 3
Units.SI.TemperatureT3oClinker temperature at the outlet of zone 3
Units.SI.PowerP3acAir power heated at (T2 + T3o)/2
Units.SI.PowerP3coCO power heated at (T2 + T3o)/2
Units.SI.PowerP3Total flue gases power at the outlet of zone 3
Units.SI.TemperatureT4oClinker temperature at the outlet for the water seal
Units.SI.TemperatureT4erWater temperature at the inlet of the water seal
RealX4H2OH2O mass fraction in the clinker at the outlet of the water seal
Units.SI.SpecificHeatCapacityCp4liqWater specific heat capacity at TEej
Units.SI.PowerP4mPower lost by the clinker during vaporisation
Units.SI.PowerP4hPower associated to the clinker humidity
Units.SI.MassFlowRateQ4vSteam mass flow rate generated by the water seal
Units.SI.SpecificEnthalpyH4Enthalpy in zone 4
Units.SI.PowerP4vPower captured by the steam in zone 4
Units.SI.MassFlowRateQO2pFlue gases O2 mass flow rate at the outlet
Units.SI.MassFlowRateQairpExcess air mass flow rate for data Qo2p
Units.SI.MassFlowRateQairsStoechiometric air mass flow rate
Units.SI.MassFlowRateQ5eH2OSteam mass flow rate at the inlet of zone 5
Units.SI.MassFlowRateQ5eCOCO mass flow rate at the inlet of zone 5
Units.SI.MassFlowRateQ5eCO2CO2 mass flow rate at the inlet of zone 5
Units.SI.MassFlowRateQ5eO2O2 mass flow rate at the inlet of zone 5
Units.SI.MassFlowRateQ5eN2N2 mass flow rate at the inlet of zone 5
Units.SI.MassFlowRateQ5eSO2SO2 mass flow rate at the inlet of zone 5
Units.SI.MassFlowRateQ5eHClHCl mass flow rate at the inlet of zone 5
Units.SI.MassFlowRateQ5eHFHF mass flow rate at the inlet of zone 5
Units.SI.MassFlowRateQ5ecendAshes mass flow rate at the inlet of zone 5
Units.SI.MassFlowRateQ5eamTotal mass flow rate at the inlet of zone 5
Units.SI.MassFlowRateQ5odO mass flow rate available in zone 5
Units.SI.MassFlowRateQ5cdC mass flow rate available in zone 5
Units.SI.MassFlowRateQ5hdH mass flow rate available in zone 5
Units.SI.MassFlowRateQ5ostStoechiométrique O mass flow rate for zone 5
Realexc5Air excess for zone 5
Units.SI.PowerP5Power released by oxydation in zone 5
Units.SI.MassFlowRateQ5sCO2CO2 mass flow rate at the outlet of zone 5
Units.SI.MassFlowRateQ5sO2O2 mass flow rate at the outlet of zone 5
Units.SI.MassFlowRateQ5sCOCO mass flow rate at the outlet of zone 5
Units.SI.PowerP5sPower released by oxydation in zone 5
RealXsfCOFlue gases CO mass fraction at the outlet of zone 5
RealXsfN21Flue gases N2 mass fraction at the outlet of zone 5
RealXsfHClFlue gases HCl mass fraction at the outlet of zone 5
RealXsfHFFlue gases HF mass fraction at the outlet of zone 5
RealXsfCENDAshes mass fraction at the outlet of zone 5
Units.SI.PowerP5aPower brought by secondary air
Units.SI.PowerP5tPower accumulated in the flue gases
RealXcorCorrective factor for the flue gases mass fractions
RealX5sH2OCCorrected flue gases H2O mass fraction
RealX5sCO2CCorrected flue gases CO2 mass fraction
RealX5sO2CCorrected flue gases O2 mass fraction
RealX5sSO2CCorrected flue gases SO2 mass fraction
RealX5sN2CCorrected flue gases N2 mass fraction
Units.SI.DensityrhonormDensity of the outgoing flue gases Masse at 0 deg C and 1 atm
RealFVN0Ashes normal volume fraction for the computation of FVN
ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_pTpro1
ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_pTpro2
ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_pTpro3
ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_pTpro4
ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_pTpro5

Revisions

Author  

Baligh El Hefni