modelSink

MultiFluids sink

Extends from ThermoSysPro.Fluid.Interfaces.PropertyInterfaces.FluidTypeVariableInterface (Interface to display the fluid type after simulation), ThermoSysPro.Fluid.Interfaces.IconColors (Colors of the static, singular and dynamic model icons).

Information

## Copyright © EDF 2002 - 2026   
## ThermoSysPro Version 4.2

Parameters

TypeNameDefaultDescription
Units.SI.TemperatureT0290Source temperature (active if option_temperature=true)
Units.SI.SpecificEnthalpyh0100000Source specific enthalpy (active if option_temperature=false)
Booleanoption_temperaturefalsetrue:temperature fixed - false:specific enthalpy fixed
Booleandiffusionfalsetrue: energy balance equation with diffusion - false: energy balance equation without diffusion
Fluid › Fluid properties
IF97RegionregionIF97Region.All_regionsIF97 regions (active for IF97 water/steam only)

Connectors

TypeNameDefaultDescription
ThermoSysPro.Fluid.Interfaces.Connectors.FluidInletC
InstrumentationAndControl.Connectors.InputRealISpecificEnthalpyOrTemperatureFixed specific enthalpy or temperature according to option_temperature

Components

TypeNameDefaultDescription
FluidTypeftype (from FluidTypeVariableInterface)fluid type
Integerfluid1 (from FluidTypeVariableInterface)Integer(ftype)Fluid number
Units.SI.MassFlowRateQFluid mass flow rate
Units.SI.AbsolutePressurePFluid pressure
Units.SI.SpecificEnthalpyhFluid specific enthalpy
Units.SI.TemperatureTFluid temperature
IntegerfluidInteger(ftype)Fluid number
RealXco2CO2 mass fraction of the fluid crossing the boundary of the control volume
RealXh2oH2O mass fraction of the fluid crossing the boundary of the control volume
RealXo2O2 mass fraction of the fluid crossing the boundary of the control volume
RealXso2SO2 mass fraction of the fluid crossing the boundary of the control volume

Revisions

Authors  

Baligh El Hefni  
Daniel Bouskela