modelSinkPQ

MultiFluids sink with fixed pressure and mass flow rate

Extends from ThermoSysPro.Fluid.Interfaces.IconColors (Colors of the static, singular and dynamic model icons).

Information

## Copyright © EDF 2002 - 2026   
## ThermoSysPro Version 4.2

Parameters

TypeNameDefaultDescription
Units.SI.AbsolutePressureP0100000Fluid pressure (active if IPressure connector is not connected)
Units.SI.MassFlowRateQ0100Mass flow (active if IMassFlow connector is not connected)
Units.SI.TemperatureT0290Source temperature (active if option_temperature=true)
Units.SI.SpecificEnthalpyh0100000Source specific enthalpy (active if option_temperature=false)
Booleanoption_temperaturefalsetrue:temperature fixed - false:specific enthalpy fixed
Booleandiffusionfalsetrue: energy balance equation with diffusion - false: energy balance equation without diffusion
Fluid › Fluid properties
IF97RegionregionIF97Region.All_regionsIF97 regions (active for IF97 water/steam only)

Connectors

TypeNameDefaultDescription
ThermoSysPro.InstrumentationAndControl.Connectors.InputRealIMassFlowFixed mass flow rate
ThermoSysPro.InstrumentationAndControl.Connectors.InputRealIPressureFixed pressure
ThermoSysPro.Fluid.Interfaces.Connectors.FluidInletC
InstrumentationAndControl.Connectors.InputRealISpecificEnthalpyOrTemperatureFixed specific enthalpy or temperature according to option_temperature

Components

TypeNameDefaultDescription
Units.SI.MassFlowRateQFluid mass flow rate
Units.SI.AbsolutePressurePFluid pressure
Units.SI.SpecificEnthalpyhFluid specific enthalpy
Units.SI.TemperatureTFluid temperature
FluidTypeftypeFluid type
IntegerfluidInteger(ftype)Fluid number
RealXco2CO2 mass fraction of the fluid crossing the boundary of the control volume
RealXh2oH2O mass fraction of the fluid crossing the boundary of the control volume
RealXo2O2 mass fraction of the fluid crossing the boundary of the control volume
RealXso2SO2 mass fraction of the fluid crossing the boundary of the control volume

Revisions

Authors  

Baligh El Hefni  
Daniel Bouskela