| Units.SI.MassFlowRate | Qee | | Cooling water mass flow rate at the inlet |
| Units.SI.SpecificEnthalpy | Hee | | Cooling water specific anthalpy at the inlet |
| Units.SI.AbsolutePressure | Pee | | Cooling water pressure at the inlet |
| Units.SI.MassFlowRate | Qep | | Drain mass flow rate at the inlet |
| Units.SI.SpecificEnthalpy | Hep | | Drain specific enthalpy at the inlet |
| Units.SI.MassFlowRate | Qev | | Vapor mass flow rate at the inlet |
| Units.SI.SpecificEnthalpy | Hev | | Vapor specific enthalpy at the inlet |
| Units.SI.MassFlowRate | Qvt | | Vapor mass flow rate leaving the turbine |
| Units.SI.SpecificEnthalpy | Hvt | | Vapor specific enthalpy leaving the turbine |
| Units.SI.MassFlowRate | Qse | | Cooling water mass flow rate at the outlet |
| Units.SI.SpecificEnthalpy | Hse | | Cooling water specific enthalpy at the outlet |
| Units.SI.AbsolutePressure | Pse | | Cooling water pressure at the outlet |
| Units.SI.MassFlowRate | Qex | | Drain mass flow rate at the outlet |
| Units.SI.SpecificEnthalpy | Hex | | Drain specific enthalpy at the outlet |
| Units.SI.AbsolutePressure | Pex | | Drain pressure at the outlet |
| Units.SI.SpecificEnthalpy | Hsate | | Water specific enthalpy at the saturation point |
| Units.SI.AbsolutePressure | Pcond | | Vapor pressure inside the condenser |
| Units.SI.Temperature | Tsat | | Water temperature at the saturation point |
| Units.SI.Temperature | Tee | | Cooling water temperature at the inlet |
| Units.SI.Temperature | Tse | | Cooling water temperature at the outlet |
| Units.SI.Density | rho_ee | | Cooling water density at the inlet |
| Units.SI.Density | rho_ex | | Water density at the extraction point |
| Units.SI.CoefficientOfHeatTransfer | KT1 | | First reference value for the exchange coefficient |
| Units.SI.CoefficientOfHeatTransfer | KT2 | | Second reference value for the exchange coefficient |
| Units.SI.CoefficientOfHeatTransfer | XKCO | | Heat transfer coefficient |
| Units.SI.SpecificEnthalpy | Hml | | Extraction water average specific enthalpy |
| Units.SI.Power | W | | Heat power released to the cold source |
| FluidType[5] | fluids | | Fluids mixing in volume |
| Units.SI.Power | Jvt | | Thermal power diffusion from inlet Cvt |
| Units.SI.Power | Jev | | Thermal power diffusion from inlet Cev |
| Units.SI.Power | Jep | | Thermal power diffusion from inlet Cep |
| Units.SI.Power | Jex | | Thermal power diffusion from outlet Cex |
| Units.SI.Power | J | | Total thermal power diffusion for the liquid in the cavity |
| Units.SI.MassFlowRate | gamma_vt | | Diffusion conductance for inlet Cvt |
| Units.SI.MassFlowRate | gamma_ev | | Diffusion conductance for inlet Cev |
| Units.SI.MassFlowRate | gamma_ep | | Diffusion conductance for inlet Cep |
| Units.SI.MassFlowRate | gamma_ex | | Diffusion conductance for outlet Cex |
| Real | rvt | | Value of r(Q/gamma) for inlet Cvt |
| Real | rev | | Value of r(Q/gamma) for inlet Cev |
| Real | rep | | Value of r(Q/gamma) for inlet Cep |
| Real | rex | | Value of r(Q/gamma) for outlet Cex |
| FluidType | ftype_p | | Cooling pipe fluid type |
| Integer | fluid_p | Integer(ftype_p) | Cooling pipe fluid number |
| ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_ph | proex | | Propriétés de l'eau |
| ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_ph | proee | | Propriétés de l'eau |
| ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_ph | prose | | Propriétés de l'eau |
| ThermoSysPro.Properties.WaterSteam.Common.PropThermoSat | lsat1 | | |
| ThermoSysPro.Properties.WaterSteam.Common.PropThermoSat | vsat1 | | |