modelStaticCondenser

Static condenser

Extends from ThermoSysPro.Fluid.Interfaces.PropertyInterfaces.WaterSteamFluidTypeParameterInterface (Interface to display the water/steam fluid type after parametrization), ThermoSysPro.Fluid.Interfaces.IconColors (Colors of the static, singular and dynamic model icons).

Information

## Copyright © EDF 2002 - 2026   
## ThermoSysPro Version 4.2   
This component model is documented in Sect. 9.7.1 of the ThermoSysPro book.

Parameters

TypeNameDefaultDescription
Units.SI.AreaSCO10000Heat exchange surface
RealCPCE0.02Pressure loss coefficient for the water side (Pa.s²/(kg.m**3))
Units.SI.Heightz0.5Water level in the condenser
Units.SI.CoefficientOfHeatTransferKCO1Reference heat exchange coefficient
Units.SI.MassFlowRateQC0100Reference mass flow rate
Units.SI.TemperatureTref293Reference temperature
RealCOPR1Reference fouling coefficient
RealCOP1Actual fouling coefficient
Units.SI.MassFlowRategamma_diff1e-4Air diffusion conductance (active if diffusion=true in neighbouring volumes)
Booleancontinuous_flow_reversalfalsetrue: continuous flow reversal - false: discontinuous flow reversal
Booleandiffusionfalsetrue: energy balance equation with diffusion - false: energy balance equation without diffusion
Fluid › Fluid properties
WaterSteamFluidTypewsftype (from WaterSteamFluidTypeParameterInterface)WaterSteamFluidType.WaterSteamWater/steam fluid type
IF97Regionregion_eeIF97Region.All_regionsIF97 region at the water inlet (active for IF97 water/steam only)
IF97Regionregion_seIF97Region.All_regionsIF97 region at the water outlet (active for IF97 water/steam only)
IF97Regionregion_exIF97Region.All_regionsIF97 region at the extraction point (active for IF97 water/steam only)

Connectors

TypeNameDefaultDescription
ThermoSysPro.Fluid.Interfaces.Connectors.FluidInletCeeCooling water inlet
ThermoSysPro.Fluid.Interfaces.Connectors.FluidOutletCseCooling water outlet
ThermoSysPro.Fluid.Interfaces.Connectors.FluidOutletCexExtraction water
ThermoSysPro.Fluid.Interfaces.Connectors.FluidInletCvtTurbine outlet
ThermoSysPro.Fluid.Interfaces.Connectors.FluidInletCepDrain inlet
ThermoSysPro.Fluid.Interfaces.Connectors.FluidInletCevVapor inlet

Components

TypeNameDefaultDescription
Units.SI.MassFlowRateQeeCooling water mass flow rate at the inlet
Units.SI.SpecificEnthalpyHeeCooling water specific anthalpy at the inlet
Units.SI.AbsolutePressurePeeCooling water pressure at the inlet
Units.SI.MassFlowRateQepDrain mass flow rate at the inlet
Units.SI.SpecificEnthalpyHepDrain specific enthalpy at the inlet
Units.SI.MassFlowRateQevVapor mass flow rate at the inlet
Units.SI.SpecificEnthalpyHevVapor specific enthalpy at the inlet
Units.SI.MassFlowRateQvtVapor mass flow rate leaving the turbine
Units.SI.SpecificEnthalpyHvtVapor specific enthalpy leaving the turbine
Units.SI.MassFlowRateQseCooling water mass flow rate at the outlet
Units.SI.SpecificEnthalpyHseCooling water specific enthalpy at the outlet
Units.SI.AbsolutePressurePseCooling water pressure at the outlet
Units.SI.MassFlowRateQexDrain mass flow rate at the outlet
Units.SI.SpecificEnthalpyHexDrain specific enthalpy at the outlet
Units.SI.AbsolutePressurePexDrain pressure at the outlet
Units.SI.SpecificEnthalpyHsateWater specific enthalpy at the saturation point
Units.SI.AbsolutePressurePcondVapor pressure inside the condenser
Units.SI.TemperatureTsatWater temperature at the saturation point
Units.SI.TemperatureTeeCooling water temperature at the inlet
Units.SI.TemperatureTseCooling water temperature at the outlet
Units.SI.Densityrho_eeCooling water density at the inlet
Units.SI.Densityrho_exWater density at the extraction point
Units.SI.CoefficientOfHeatTransferKT1First reference value for the exchange coefficient
Units.SI.CoefficientOfHeatTransferKT2Second reference value for the exchange coefficient
Units.SI.CoefficientOfHeatTransferXKCOHeat transfer coefficient
Units.SI.SpecificEnthalpyHmlExtraction water average specific enthalpy
Units.SI.PowerWHeat power released to the cold source
FluidType[5]fluidsFluids mixing in volume
Units.SI.PowerJvtThermal power diffusion from inlet Cvt
Units.SI.PowerJevThermal power diffusion from inlet Cev
Units.SI.PowerJepThermal power diffusion from inlet Cep
Units.SI.PowerJexThermal power diffusion from outlet Cex
Units.SI.PowerJTotal thermal power diffusion for the liquid in the cavity
Units.SI.MassFlowRategamma_vtDiffusion conductance for inlet Cvt
Units.SI.MassFlowRategamma_evDiffusion conductance for inlet Cev
Units.SI.MassFlowRategamma_epDiffusion conductance for inlet Cep
Units.SI.MassFlowRategamma_exDiffusion conductance for outlet Cex
RealrvtValue of r(Q/gamma) for inlet Cvt
RealrevValue of r(Q/gamma) for inlet Cev
RealrepValue of r(Q/gamma) for inlet Cep
RealrexValue of r(Q/gamma) for outlet Cex
FluidTypeftype_pCooling pipe fluid type
Integerfluid_pInteger(ftype_p)Cooling pipe fluid number
ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_phproexPropriétés de l'eau
ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_phproeePropriétés de l'eau
ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_phprosePropriétés de l'eau
ThermoSysPro.Properties.WaterSteam.Common.PropThermoSatlsat1
ThermoSysPro.Properties.WaterSteam.Common.PropThermoSatvsat1

Revisions

Author  

Baligh El Hefni