modelDynamicExchangerWaterSteamFlueGases
Dynamic exchanger water/steam - flue gases
Information
## Copyright © EDF 2002 - 2026 ## ThermoSysPro Version 4.2
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Units.SI.Length | L | 1 | Exchanger length |
| Units.SI.Position | z1 | 0 | Exchanger inlet altitude |
| Units.SI.Position | z2 | 0 | Exchanger outlet altitude |
| Integer | Ns | 1 | Numver of segments |
| Units.SI.Diameter | Dint | 0.1 | Pipe internal diameter |
| Integer | Ntubes | 1 | Number of pipes in parallel |
Connectors
Components
| Type | Name | Default | Description |
|---|---|---|---|
| ThermoSysPro.FlueGases.HeatExchangers.StaticWallFlueGasesExchanger | ExchangerFlueGasesMetal | ||
| ThermoSysPro.Thermal.HeatTransfer.HeatExchangerWall | ExchangerWall | ||
| ThermoSysPro.WaterSteam.HeatExchangers.DynamicTwoPhaseFlowPipe | TwoPhaseFlowPipe |
Revisions
Authors Guillaume Larrignon Baligh El Hefni