recorddata

constant IF97 data and region limits

Extends from Modelica.Icons.Record (Icon for records).

Information

Record description  
Constants needed in the international steam properties IF97.  
                           SCRIT and HCRIT are calculated from Helmholtz function for region 3.  
Version Info and Revision history  


First implemented: July, 2000  
       by Hubertus Tummescheit  
         

Author: Hubertus Tummescheit,   
      Modelon AB  
      Ideon Science Park  
      SE-22370 Lund, Sweden  
      email: hubertus@modelon.se  
   

Initial version: July 2000  
Documentation added: December 2002  


## Copyright © EDF 2002 - 2025

## ThermoSysPro Version 4.2

Parameters

TypeNameDefaultDescription
Units.SI.SpecificHeatCapacityRH2O461.526specific gas constant of water vapour
Units.SI.MolarMassMH2O0.01801528molar weight of water
Units.SI.TemperatureTSTAR11386.0normalization temperature for region 1 IF97
Units.SI.PressurePSTAR116.53e6normalization pressure for region 1 IF97
Units.SI.TemperatureTSTAR2540.0normalization temperature for region 2 IF97
Units.SI.PressurePSTAR21.0e6normalization pressure for region 2 IF97
Units.SI.TemperatureTSTAR51000.0normalization temperature for region 5 IF97
Units.SI.PressurePSTAR51.0e6normalization pressure for region 5 IF97
Units.SI.SpecificEnthalpyHSTAR12.5e6normalization specific enthalpy for region 1 IF97
RealIPSTAR1.0e-6normalization pressure for inverse function in region 2 IF97
RealIHSTAR5.0e-7normalization specific enthalpy for inverse function in region 2 IF97
Units.SI.TemperatureTLIMIT1623.15temperature limit between regions 1 and 3
Units.SI.TemperatureTLIMIT21073.15temperature limit between regions 2 and 5
Units.SI.TemperatureTLIMIT52273.15upper temperature limit of 5
Units.SI.PressurePLIMIT1100.0e6upper pressure limit for regions 1, 2 and 3
Units.SI.PressurePLIMIT4A16.5292e6pressure limit between regions 1 and 2, important for for two-phase (region 4)
Units.SI.PressurePLIMIT510.0e6upper limit of valid pressure in region 5
Units.SI.PressurePCRIT22064000.0the critical pressure
Units.SI.TemperatureTCRIT647.096the critical temperature
Units.SI.DensityDCRIT322.0the critical density
Units.SI.SpecificEntropySCRIT4412.02148223476the calculated specific entropy at the critical point
Units.SI.SpecificEnthalpyHCRIT2087546.84511715the calculated specific enthalpy at the critical point
Realnarray(0.34805185628969e3, -0.11671859879975e1, 0.10192970039326e-2, 0.57254459862746e3, 0.13918839778870e2)polynomial coefficients for boundary between regions 2 and 3